» Articles » PMID: 35329271

Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study

Overview
Publisher MDPI
Date 2022 Mar 25
PMID 35329271
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to assess the accuracy and reliability of tooth width measurements and Bolton Indices delivered by the Clin-Check Pro 6.0 software (Align Technology, San José, CA, USA). Fifty-four plaster casts were selected and measured with a manual calliper by a trained and calibrated observer. The data gathered were compared with those delivered by the software on the corresponding fifty-four virtual casts. The method reliability of the software was assessed by comparing the measurements performed by the software on 201 pairs of clin-checks corresponding to two consecutive treatment phases. Accuracy and reliability were statistically assessed using a mixed model. The software tends to provide larger widths compared with the manual method. Statistically significant differences were found in 23 teeth. At a global level, the mean difference between the methods was -0.19 mm, with a Dahlberg error of 0.24 mm and an intraclass correlation coefficient of 0.98. The Bolton Indices delivered by the two methods had a moderate correlation (ICC = 0.59; 0.69). The within method reliability of the software was extremely high. Tooth width measurements delivered by the software, despite the positive bias, can be considered accurate and clinically acceptable for all teeth except molars. The Bolton Indices made available by the software are not accurate and clinically acceptable, especially in the case of mandibular excess.

Citing Articles

Diagnostic performance of ClinCheck, Dolphin Imaging, and 3D Slicer software for Bolton discrepancy analysis.

Teixeira Santana T, Copello F, Maranon-Vasquez G, Issamu Nojima L, Franzotti SantAnna E Angle Orthod. 2024; 95(1):51-56.

PMID: 39317378 PMC: 11662356. DOI: 10.2319/022724-156.1.


The Effect of Sintering on Zirconia Manufactured via Suspension-Enclosing Projection Stereolithography for Dental Applications: An In Vitro Study.

Unnadkat A, Kirby L, Kulanthaivel S, Rysavy O, Tsujimoto A, Song X Materials (Basel). 2024; 17(1).

PMID: 38203868 PMC: 10779720. DOI: 10.3390/ma17010014.


Prosthetic Oral Rehabilitation with CAD/CAM Suprastructures in Patients with Severe Tissue Deficits: A Case Series.

Laurila M, Mantynen P, Mauno J, Suojanen J Dent J (Basel). 2023; 11(12).

PMID: 38132427 PMC: 10742847. DOI: 10.3390/dj11120289.


Three-Dimensional Scanning Accuracy of Intraoral Scanners for Dental Implant Scan Bodies-An Original Study.

Rotaru C, Bica E, Butnarasu C, Sandulescu M Medicina (Kaunas). 2023; 59(11).

PMID: 38004086 PMC: 10673438. DOI: 10.3390/medicina59112037.

References
1.
Bootvong K, Liu Z, McGrath C, Hagg U, Wong R, Bendeus M . Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity. Eur J Orthod. 2010; 32(5):589-95. DOI: 10.1093/ejo/cjp159. View

2.
Soto-Alvarez C, Fonseca G, Viciano J, Aleman I, Rojas-Torres J, Zuniga M . Reliability, reproducibility and validity of the conventional buccolingual and mesiodistal measurements on 3D dental digital models obtained from intra-oral 3D scanner. Arch Oral Biol. 2019; 109:104575. DOI: 10.1016/j.archoralbio.2019.104575. View

3.
Koretsi V, Tingelhoff L, Proff P, Kirschneck C . Intra-observer reliability and agreement of manual and digital orthodontic model analysis. Eur J Orthod. 2017; 40(1):52-57. DOI: 10.1093/ejo/cjx040. View

4.
Koretsi V, Kirschbauer C, Proff P, Kirschneck C . Reliability and intra-examiner agreement of orthodontic model analysis with a digital caliper on plaster and printed dental models. Clin Oral Investig. 2018; 23(8):3387-3396. DOI: 10.1007/s00784-018-2772-8. View

5.
Asquith J, Gillgrass T, Mossey P . Three-dimensional imaging of orthodontic models: a pilot study. Eur J Orthod. 2007; 29(5):517-22. DOI: 10.1093/ejo/cjm044. View