» Articles » PMID: 35261818

Titanium Dioxide Dental Implants Surfaces Related Oxidative Stress in Bone Remodeling: a Systematic Review

Overview
Journal PeerJ
Date 2022 Mar 9
PMID 35261818
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Titanium dioxide dental implants have a controversial effect on reactive oxygen species (ROS) production. ROS is necessary for cellular signal transmission and proper metabolism, but also has the ability to cause cell death as well as DNA, RNA, and proteins damage by excessive oxidative stress. This study aimed to systematically review the effect of titanium dioxide dental implant-induced oxidative stress and its role on the osteogenesis-angiogenesis coupling in bone remodeling.

Methods: This systematic review was performed conforming to preferred reporting items for systematic review and meta-analysis (PRISMA) model. Four different databases (PubMed, Science Direct, Scopus and Medline databases) as well as manual searching were adopted. Relevant studies from January 2000 till September 2021 were retrieved. Critical Appraisal Skills Programme (CASP) was used to assess the quality of the selected studies.

Results: Out of 755 articles, only 14 which met the eligibility criteria were included. Six studies found that titanium dioxide nanotube (TNT) reduced oxidative stress and promoted osteoblastic activity through its effect on Wnt, mitogen-activated protein kinase (MAPK) and forkhead box protein O1 (FoxO1) signaling pathways. On the other hand, three studies confirmed that titanium dioxide nanoparticles (TiONPs) induce oxidative stress, reduce ostegenesis and impair antioxidant defense system as a significant negative correlation was found between decreased SIR3 protein level and increased superoxide (O ). Moreover, five studies proved that titanium implant alloy enhances the generation of ROS and induces cytotoxicity of osteoblast cells via its effect on NOX pathway.

Conclusion: TiONPs stimulate a wide array of oxidative stress related pathways. Scientific evidence are in favor to support the use of TiO nanotube-coated titanium implants to reduce oxidative stress and promote osteogenesis in bone remodeling. To validate the cellular and molecular cross talk in bone remodeling of the present review, well-controlled clinical trials with a large sample size are required.

Citing Articles

Impact of Titanium Plate Fixation on Diacylglycerol and Growth Factor Levels in the Periosteum of the Mandible and Maxilla in Patients with Dentofacial Deformities After Jaw Osteotomies.

Antonowicz B, Borys J, Roszczyc-Owsiejczuk K, Lukaszuk K, Zalewska A, Blachnio-Zabielska A Int J Mol Sci. 2025; 26(5).

PMID: 40076643 PMC: 11900233. DOI: 10.3390/ijms26052020.


Potential role of metal nanoparticles in treatment of peri-implant mucositis and peri-implantitis.

Hosseini Hooshiar M, Mozaffari A, Ahmed M, Kareem R, Jaber Zrzo A, Mansoor A Biomed Eng Online. 2024; 23(1):101.

PMID: 39396020 PMC: 11470642. DOI: 10.1186/s12938-024-01294-0.


Application of nanoparticles as surface modifiers of dental implants for revascularization/regeneration of bone.

Soe Z, Wahyudi R, Mattheos N, Lertpimonchai A, Everts V, Tompkins K BMC Oral Health. 2024; 24(1):1175.

PMID: 39367468 PMC: 11451240. DOI: 10.1186/s12903-024-04966-4.


Investigating the influence of titanium particle size and concentration on osteogenic response of human osteoblasts - in vitro study.

Sheela S, Kheder W, Samsudin A Biomater Investig Dent. 2024; 11:40843.

PMID: 38903775 PMC: 11187976. DOI: 10.2340/biid.v11.40843.


Inflammatory, Oxidative Stress and Small Cellular Particle Response in HUVEC Induced by Debris from Endoprosthesis Processing.

Jan Z, Hocevar M, Kononenko V, Michelini S, Repar N, Caf M Materials (Basel). 2023; 16(9).

PMID: 37176169 PMC: 10179554. DOI: 10.3390/ma16093287.


References
1.
Nucera R, Giudice A, Bellocchio M, Spinuzza P, Caprioglio A, Cordasco G . Diagnostic concordance between skeletal cephalometrics, radiograph-based soft-tissue cephalometrics, and photograph-based soft-tissue cephalometrics. Eur J Orthod. 2016; 39(4):352-357. DOI: 10.1093/ejo/cjw072. View

2.
McHugh M . Interrater reliability: the kappa statistic. Biochem Med (Zagreb). 2012; 22(3):276-82. PMC: 3900052. View

3.
Huang J, Li R, Yang J, Cai M, Lee Y, Wang A . Bioadaptation of implants to In vitro and In vivo oxidative stress pathological conditions via nanotopography-induced FoxO1 signaling pathways to enhance Osteoimmunal regeneration. Bioact Mater. 2021; 6(10):3164-3176. PMC: 7970012. DOI: 10.1016/j.bioactmat.2021.02.023. View

4.
Yu Y, Shen X, Luo Z, Hu Y, Li M, Ma P . Osteogenesis potential of different titania nanotubes in oxidative stress microenvironment. Biomaterials. 2018; 167:44-57. DOI: 10.1016/j.biomaterials.2018.03.024. View

5.
Mouthuy P, Snelling S, Dakin S, Milkovic L, cipak Gasparovic A, Carr A . Biocompatibility of implantable materials: An oxidative stress viewpoint. Biomaterials. 2016; 109:55-68. DOI: 10.1016/j.biomaterials.2016.09.010. View