» Articles » PMID: 35260937

Creatinine Standardization: a Key Consideration in Evaluating Whole Blood Creatinine Monitoring Systems for CKD Screening

Overview
Specialty Chemistry
Date 2022 Mar 9
PMID 35260937
Authors
Affiliations
Soon will be listed here.
Abstract

Early detection of CKD using point of care creatinine and eGFR testing improves patient management outcomes. We undertook a field study to evaluate the use of a whole blood creatinine/eGFR device to screen a rural Nicaraguan population to determine the variability between creatinine methods and specimen types. All specimens including capillary and venous dried blood spots (DBS) were tested with an isotope dilution liquid chromatography mass spectrometry (ID-LCMS) gold standard method. This is to our knowledge the first time a capillary whole blood (POC) method has been directly compared to the gold standard IDMS method, through the novel approach of using dried blood spots. Capillary and venous whole blood specimens were obtained and tested directly with the BCMS method, and then, DBS samples were prepared. Venous plasma specimens were tested using three laboratory analyzer creatinine methods. DBS were sent to the site performing ID-LCMS. Control samples were also prepared to assess the stability of shipment and storage of DBS. The ID-LCMS method was aligned using primary and secondary standards. Sixty-six (66) patients participated in the study, and the CKD prevalence rate was 7.8%. While all creatinine methods showed a good correlation to ID-LCMS, there was a positive bias (mean absolute bias range: 0.21-0.63 mg/dL). All methods used were 100% sensitive, but specificity varied from 62.7 to 94.9% with PPV ranging from 25 to 62.5%. A correction factor was used to align the values from each method to ID-LCMS which improved the specificity of each method. This study used a unique DBS approach to align capillary whole blood creatinine to ID-LCMS. To ensure reliability of BCMS for identifying screened patients with CKD, it is important to establish IDMS traceability and alignment prior to undertaking CKD studies.

Citing Articles

A Systematic Literature Review on the Use of Dried Biofluid Microsampling in Patients With Kidney Disease.

Lamond M, Chetwynd A, Salama A, Oni L J Clin Lab Anal. 2024; 38(7):e25032.

PMID: 38525922 PMC: 11033336. DOI: 10.1002/jcla.25032.

References
1.
Liyanage T, Ninomiya T, Jha V, Neal B, Patrice H, Okpechi I . Worldwide access to treatment for end-stage kidney disease: a systematic review. Lancet. 2015; 385(9981):1975-82. DOI: 10.1016/S0140-6736(14)61601-9. View

2.
Gonzalez-Bedat M, Rosa-Diez G, Pecoits-Filho R, Ferreiro A, Garcia-Garcia G, Cusumano A . Burden of disease: prevalence and incidence of ESRD in Latin America. Clin Nephrol. 2015; 83(7 Suppl 1):3-6. DOI: 10.5414/cnp83s003. View

3.
DOrazio P, Conant J, Cervera J . Measurement of creatinine in whole blood samples supplemented to achieve increased creatinine concentrations. Clin Chem. 2008; 54(2):451-2. DOI: 10.1373/clinchem.2007.096594. View

4.
Lee E, Collier C, White C . Creatinine Assay Attainment of Analytical Performance Goals Following Implementation of IDMS Standardization: Further Improvements Required. Can J Kidney Health Dis. 2017; 4:2054358117693353. PMC: 5347424. DOI: 10.1177/2054358117693353. View

5.
Myers G, Miller W, Coresh J, Fleming J, Greenberg N, Greene T . Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem. 2005; 52(1):5-18. DOI: 10.1373/clinchem.2005.0525144. View