» Articles » PMID: 35233906

Development, Validation, and Reproducibility of the Pullback Pressure Gradient (PPG) Derived from Manual Fractional Flow Reserve Pullbacks

Abstract

Fractional flow reserve (FFR) pullbacks assess the location and magnitude of pressure drops along the coronary artery. The pullback pressure gradient (PPG) quantifies the FFR pullback curve and provides a numeric expression of focal versus diffuse coronary artery disease. This study aims (1) to validate the PPG using manual FFR pullbacks compared with motorized FFR pullbacks as a reference; and (2) to determine the intra- and interoperator reproducibility of the PPG derived from manual FFR pullbacks. Patients with stable coronary artery disease and an FFR ≤ 0.80 were included. All patients underwent FFR pullback evaluation either with a motorized device or manually, depending on the study cohort. The agreement of the PPG between repeated pullbacks was assessed using the Bland-Altman method. Overall, 116 FFR pullback maneuvers (96 manual and 20 motorized) were analyzed. There was excellent agreement between the PPG derived from manual and motorized pullbacks (mean difference -0.01 ± 0.07, 95% limits of agreement [LOA] -0.14 to 0.12). The intra- and interoperator reproducibility of PPG derived from manual pullbacks were excellent (mean difference <0.01, 95% LOA -0.11 to 0.12, and mean difference <0.01, 95% LOA -0.12 to 0.11, respectively). The duration of the pullback maneuver did not impact the reproducibility of the PPG (r = 0.12, 95% CI: -0.29 to 0.49, p = 0.567). Manual pullbacks allow for an accurate PPG calculation. The inter- and intraoperator reproducibility of PPG derived from manual pullbacks were excellent.

Citing Articles

Pullback Pressure Gradient-An Emerging Concept in Patients with Coronary Artery Disease.

Omari M, Ibrahem A, Bawamia B, Cartlidge T, Bagnall A, Purcell I Rev Cardiovasc Med. 2024; 25(8):278.

PMID: 39228493 PMC: 11366980. DOI: 10.31083/j.rcm2508278.


Angiography-derived physiological patterns of coronary artery disease: implications with post-stenting physiology and long-term clinical outcomes.

Fezzi S, Del Sole P, Burzotta F, Leone A, Ding D, Terentes-Printzios D Clin Res Cardiol. 2024; 113(12):1745-1756.

PMID: 39102003 PMC: 11579185. DOI: 10.1007/s00392-024-02500-8.


Influence of Pathophysiologic Patterns of Coronary Artery Disease on Immediate Percutaneous Coronary Intervention Outcomes.

Collet C, Munhoz D, Mizukami T, Sonck J, Matsuo H, Shinke T Circulation. 2024; 150(8):586-597.

PMID: 38742491 PMC: 11335079. DOI: 10.1161/CIRCULATIONAHA.124.069450.


Association Between Automated 3D Measurement of Coronary Luminal Narrowing and Risk of Future Myocardial Infarction.

Candreva A, Lodi Rizzini M, Calo K, Pagnoni M, Munhoz D, Chiastra C J Cardiovasc Transl Res. 2024; 17(4):893-900.

PMID: 38427153 PMC: 11371893. DOI: 10.1007/s12265-024-10500-2.


[A method for photoplethysmography signal quality assessment fusing multi-class features with multi-scale series information].

Qi Y, Zhang A, Ma Y, Wang H, Li J, Chen C Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2023; 40(3):536-543.

PMID: 37380394 PMC: 10307609. DOI: 10.7507/1001-5515.202211054.