» Articles » PMID: 35211466

Optimization of Mechanical Tissue Dissociation Using an Integrated Microfluidic Device for Improved Generation of Single Cells Following Digestion

Overview
Date 2022 Feb 25
PMID 35211466
Authors
Affiliations
Soon will be listed here.
Abstract

The dissociation of tissue and cell aggregates into single cells is of high interest for single cell analysis studies, primary cultures, tissue engineering, and regenerative medicine. However, current methods are slow, poorly controlled, variable, and can introduce artifacts. We previously developed a microfluidic device that contains two separate dissociation modules, a branching channel array and nylon mesh filters, which was used as a polishing step after tissue processing with a microfluidic digestion device. Here, we employed the integrated disaggregation and filtration (IDF) device as a standalone method with both cell aggregates and traditionally digested tissue to perform a well-controlled and detailed study into the effect of mechanical forces on dissociation, including modulation of flow rate, device pass number, and even the mechanism. Using a strongly cohesive cell aggregate model, we found that single cell recovery was highest using flow rates exceeding 40 ml/min and multiple passes through the filter module, either with or without the channel module. For minced and digested kidney tissue, recovery of diverse cell types was maximal using multiple passes through the channel module and only a single pass through the filter module. Notably, we found that epithelial cell recovery from the optimized IDF device alone exceeded our previous efforts, and this result was maintained after reducing digestion time to 20 min. However, endothelial cells and leukocytes still required extended digestion time for maximal recover. These findings highlight the significance of parameter optimization to achieve the highest cell yield and viability based on tissue sample size, extracellular matrix content, and strength of cell-cell interactions.

Citing Articles

Investigation of the Effect of High Shear Stress on Mesenchymal Stem Cells Using a Rotational Rheometer in a Small-Angle Cone-Plate Configuration.

Mand M, Hahn O, Meyer J, Peters K, Seitz H Bioengineering (Basel). 2024; 11(10).

PMID: 39451387 PMC: 11504001. DOI: 10.3390/bioengineering11101011.


Drosophila CASK regulates brain size and neuronal morphogenesis, providing a genetic model of postnatal microcephaly suitable for drug discovery.

Tello J, Jiang L, Zohar Y, Restifo L Neural Dev. 2023; 18(1):6.

PMID: 37805506 PMC: 10559581. DOI: 10.1186/s13064-023-00174-y.


Improving Transcriptome Fidelity Following Synovial Tissue Disaggregation.

Boyle D, Prideaux E, Hillman J, Wang W, Firestein G Front Med (Lausanne). 2022; 9:919748.

PMID: 36035425 PMC: 9400013. DOI: 10.3389/fmed.2022.919748.

References
1.
Lin C, Lee D, Chang H, Chiu I, Hsu C . Single-cell enzyme-free dissociation of neurospheres using a microfluidic chip. Anal Chem. 2013; 85(24):11920-8. DOI: 10.1021/ac402724b. View

2.
Wallman L, Akesson E, Ceric D, Andersson P, Day K, Hovatta O . Biogrid--a microfluidic device for large-scale enzyme-free dissociation of stem cell aggregates. Lab Chip. 2011; 11(19):3241-8. DOI: 10.1039/c1lc20316a. View

3.
van den Brink S, Sage F, Vertesy A, Spanjaard B, Peterson-Maduro J, Baron C . Single-cell sequencing reveals dissociation-induced gene expression in tissue subpopulations. Nat Methods. 2017; 14(10):935-936. DOI: 10.1038/nmeth.4437. View

4.
Heath J, Ribas A, Mischel P . Single-cell analysis tools for drug discovery and development. Nat Rev Drug Discov. 2015; 15(3):204-16. PMC: 4883669. DOI: 10.1038/nrd.2015.16. View

5.
Khademhosseini A, Langer R, Borenstein J, Vacanti J . Microscale technologies for tissue engineering and biology. Proc Natl Acad Sci U S A. 2006; 103(8):2480-7. PMC: 1413775. DOI: 10.1073/pnas.0507681102. View