» Articles » PMID: 35204519

Impact of Macroscopic On-Site Evaluation (MOSE) on Accuracy of Endoscopic Ultrasound-Guided Fine-Needle Biopsy (EUS-FNB) of Pancreatic and Extrapancreatic Solid Lesions: A Prospective Study

Abstract

This is a prospective and comparative study including 76 consecutive patients performing EUS-FNB for pancreatic and extrapancreatic solid lesions, randomized by alternate allocation to macroscopic on-site evaluation (MOSE) (40 patients) or to a conventional technique (40 patients), with three passes each. MOSE samples were differentiated into score 0: no visible material, score 1: only necrotic or haematic material, score 2: white core tissue ≤ 2 mm, or score 3: white core tissue > 2 mm. The conventional technique consisted in pushing all the needle content into a test tube for evaluation by the pathologist. In both groups, a 22-25 Gauge Franseen-tip needle (Acquire, Boston Scientific Co., Natick, MA, USA) was used. The study evaluated the diagnostic accuracy and adequacy of MOSE compared to the conventional technique and whether MOSE could optimize the number of passes during EUS-FNB. : The analysis was performed on 76 patients (38 MOSE, 38 conventional). The overall diagnostic adequacy was 94.7% (72/76) and accuracy was 84.2% (64/76). The diagnostic accuracy was similar in the two groups: MOSE 86.8% (33/38 lesions), vs. conventional 81.6%, 31/38 lesions, = 0.76). Regarding diagnostic adequacy, the MOSE technique was 97.4% (111/114 passes) compared to 92.1% (105/114 passes) with the conventional technique, = 0.06. The accuracy increased according to the MOSE score evaluation: it was 43.5%, 65.5% and 78.3% in patients with score 1, score 2, and score 3, respectively. Moreover, if in the first two passes the MOSE score was 2 or 3, the accuracy was 82.6% (20/23), and upon adding a third pass, the accuracy increased to 87% (20/23), which was not significantly different from the general accuracy of the MOSE samples (86.8%) ( = 0.86). : The MOSE score showed a comparable diagnostic accuracy to the conventional technique. However, MOSE allows endoscopists to perform an inspective evaluation of the material, tends to perform better than the conventional technique in terms of diagnostic adequacy, and may potentially reduce the number of passes.

Citing Articles

Role of macroscopic on-site evaluation of endoscopic ultrasound-guided fine-needle aspiration/biopsy: Results of a multicentric prospective study.

Okasha H, Hussein H, Ragab K, Abdallah O, Rouibaa F, Mohamed B World J Gastrointest Endosc. 2024; 16(11):595-606.

PMID: 39600556 PMC: 11586721. DOI: 10.4253/wjge.v16.i11.595.


Fine-needle aspiration technique under endoscopic ultrasound guidance: A technical approach for RNA profiling of pancreatic neoplasms.

Seyfedinova S, Freylikhman O, Sokolnikova P, Samochernykh K, Kostareva A, Kalinina O World J Gastrointest Oncol. 2024; 16(6):2663-2672.

PMID: 38994174 PMC: 11236257. DOI: 10.4251/wjgo.v16.i6.2663.


EUS-Guided Diagnosis of Gastric Subepithelial Lesions, What Is New?.

Vasilakis T, Ziogas D, Tziatzios G, Gkolfakis P, Koukoulioti E, Kapizioni C Diagnostics (Basel). 2023; 13(13).

PMID: 37443568 PMC: 10340322. DOI: 10.3390/diagnostics13132176.


Cheesy material on macroscopic on-site evaluation after endoscopic ultrasound-guided fine-needle biopsy: Don't miss the tuberculosis.

Delsa H, Bellahammou K, Okasha H, Ghalim F World J Clin Cases. 2023; 11(10):2181-2188.

PMID: 37122512 PMC: 10131024. DOI: 10.12998/wjcc.v11.i10.2181.

References
1.
Khan M, Grimm I, Ali B, Nollan R, Tombazzi C, Ismail M . A meta-analysis of endoscopic ultrasound-fine-needle aspiration compared to endoscopic ultrasound-fine-needle biopsy: diagnostic yield and the value of onsite cytopathological assessment. Endosc Int Open. 2017; 5(5):E363-E375. PMC: 5425293. DOI: 10.1055/s-0043-101693. View

2.
Crino S, Manfrin E, Scarpa A, Baldaque-Silva F, Carrara S, de Nucci G . EUS-FNB with or without on-site evaluation for the diagnosis of solid pancreatic lesions (FROSENOR): Protocol for a multicenter randomized non-inferiority trial. Dig Liver Dis. 2019; 51(6):901-906. DOI: 10.1016/j.dld.2019.03.008. View

3.
Kaneko J, Ishiwatari H, Sasaki K, Yasuda I, Takahashi K, Imura J . Macroscopic visible core length can predict the histological sample quantity in endoscopic ultrasound-guided tissue acquisition: Multicenter prospective study. Dig Endosc. 2021; 34(3):622-631. DOI: 10.1111/den.14116. View

4.
Kaneko J, Ishiwatari H, Sasaki K, Satoh T, Sato J, Matsubayashi H . Macroscopic on-site evaluation of biopsy specimens for accurate pathological diagnosis during EUS-guided fine needle biopsy using 22-G Franseen needle. Endosc Ultrasound. 2020; 9(6):385-391. PMC: 7811705. DOI: 10.4103/eus.eus_49_20. View

5.
van Riet P, Erler N, Bruno M, Cahen D . Comparison of fine-needle aspiration and fine-needle biopsy devices for endoscopic ultrasound-guided sampling of solid lesions: a systemic review and meta-analysis. Endoscopy. 2020; 53(4):411-423. DOI: 10.1055/a-1206-5552. View