Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation-A Retrospective Comparison with Conventional Pedicle Screw Implantation

Overview
Journal Global Spine J
Publisher Sage Publications
Date 2022 Feb 23
PMID 35193407
Authors
Affiliations
Soon will be listed here.
Abstract

Study Design: A Retrospective Cohort Study.

Objective: To introduce a new Doppler sonography-assisted pedicle screw fixation technique that enables vertebral artery (VA) monitoring during surgery and compares the accuracies of Doppler sonography-assisted cervical pedicle screw fixation and the conventional technique.

Methods: This retrospective study was performed on 164 consecutive patients that underwent pedicle-based screw fixation from C2 to C6 between January 2013 and August 2020. Surgery was performed without intraoperative Doppler sonography in 84 cases (the Control group) or with intraoperative Doppler sonography in 80 cases (the Doppler group). Proper positioning of pedicle screws was graded, and the incidences of VA injury and screw breach in the Control and Doppler groups were compared.

Results: Three hundred and ninety-nine screws were placed in the 164 patients (Doppler, 186 screws; Control, 213 screws). The percentages of well-positioned screws in the two groups were significantly different (Doppler, 97.8%; Control, 85.0%). There were two cases of VA injury in the Control group, an incidence of 2.4%, but no case in the Doppler group.

Conclusion: Doppler sonography can be used intraoperatively to help guide the trajectory of the cervical pedicle screw insertion. It can detect the VA inside the screw trajectory and may reduce the risk of VA injury during cervical pedicle screw fixation.

Citing Articles

A novel radiographic analysis system for subaxial cervical spine pedicle screw placement.

Ding B, Zhou T, Ma H, Zhao J J Orthop Surg Res. 2023; 18(1):581.

PMID: 37553693 PMC: 10408217. DOI: 10.1186/s13018-023-03999-9.

References
1.
Reinhold M, Bach C, Audige L, Bale R, Attal R, Blauth M . Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature. Eur Spine J. 2008; 17(4):564-75. PMC: 2295280. DOI: 10.1007/s00586-008-0584-2. View

2.
Zhang Z . Freehand Pedicle Screw Placement Using a Universal Entry Point and Sagittal and Axial Trajectory for All Subaxial Cervical, Thoracic and Lumbosacral Spines. Orthop Surg. 2019; 12(1):141-152. PMC: 7031565. DOI: 10.1111/os.12599. View

3.
Kim J, Lee H, Kim J, Hong J . Quantitative analysis of unusual entrance of the vertebral artery into the cervical foramen (V2 segment) and its clinical implications. Eur Spine J. 2016; 25(12):4188-4194. DOI: 10.1007/s00586-016-4708-9. View

4.
Lee H, Kim I, Sung J, Lee S, Hong J . Significance of multimodal intraoperative monitoring for the posterior cervical spine surgery. Clin Neurol Neurosurg. 2016; 143:9-14. DOI: 10.1016/j.clineuro.2016.02.007. View

5.
Hong J, Lee S, Son B, Sung J, Yang S, Kim I . Analysis of anatomical variations of bone and vascular structures around the posterior atlantal arch using three-dimensional computed tomography angiography. J Neurosurg Spine. 2008; 8(3):230-6. DOI: 10.3171/SPI/2008/8/3/230. View