Coronary CT Angiography with Photon-counting CT: First-In-Human Results
Authors
Affiliations
Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images ( < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 See also the editorial by Sandfort and Bluemke in this issue.
Role of photon-counting computed tomography in pediatric cardiovascular imaging.
Perera Molligoda Arachchige A, Verma Y World J Clin Pediatr. 2025; 14(1):99288.
PMID: 40059896 PMC: 11686577. DOI: 10.5409/wjcp.v14.i1.99288.
Sasaki T, Kuno H, Nomura K, Muramatsu Y, Aokage K, Samejima J Jpn J Radiol. 2025; .
PMID: 40053285 DOI: 10.1007/s11604-025-01759-9.
Oda S, Funama Y, Kojima S, Yokoi K, Takahashi I, Aoki Y J Clin Imaging Sci. 2025; 15:8.
PMID: 40041436 PMC: 11878665. DOI: 10.25259/JCIS_157_2024.
Devkota L, Bhavane R, Badea C, Tanifum E, Annapragada A, Ghaghada K Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2025; 17(1):e70004.
PMID: 39948059 PMC: 11874078. DOI: 10.1002/wnan.70004.
Matsuyama T, Nagata H, Ozawa Y, Ito Y, Kimata H, Fujii K Eur Radiol. 2025; .
PMID: 39903239 DOI: 10.1007/s00330-025-11376-9.