EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach

Overview
Specialty Neurology
Date 2022 Feb 14
PMID 35154587
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Several computer-aided diagnosis systems for depression are suggested for use by clinicians to authorize the diagnosis. EEG may be used as an objective analysis tool for identifying depression in the initial stage to avoid it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems.

Methods: This work proposes a novel denoising method based on Empirical Mode Decomposition (EMD) (with Detrended Fluctuation Analysis (DFA) and wavelet packet transform. Initially, real EEG recordings corresponding to depression patients are decomposed into various mode functions by applying EMD. Then, DFA is used as the mode selection criteria. Further Wavelet Packets Decomposition (WPD)-based evaluation is applied to extract the cleaner signal.

Results: Simulations were conducted on real EEG databases for depression to demonstrate the effects of the proposed techniques. To conclude the efficacy of the proposed technique, SNR and MAE were identified. The obtained results indicated improved signal-to-noise ratio and lower values of MAE for the combined EMD-DFA-WPD technique. Additionally, Random Forest and SVM (Support Vector Machine)-based classification revealed the improved accuracy of 98.51% and 98.10% for the proposed denoising technique. Whereas the accuracy of the EMD- DFA is 98.01% and 95.81% and EMD combined with DWT technique equaled98.0% and 97.21% for the EMD- DFA technique for RF and SVM, respectively, compared to the proposed method. Furthermore, the classification performance for both classifiers was compared with and without denoising to highlight the effects of the proposed technique.

Conclusion: Proposed denoising system results in better classification of depressed and healthy individuals resulting in a better diagnosing system. These results can be further analyzed using other approaches as a solution to the mode mixing problem of the EMD approach.

Citing Articles

Methods for motion artifact reduction in online brain-computer interface experiments: a systematic review.

Schmoigl-Tonis M, Schranz C, Muller-Putz G Front Hum Neurosci. 2023; 17:1251690.

PMID: 37920561 PMC: 10619676. DOI: 10.3389/fnhum.2023.1251690.


Electroencephalogram-based objective assessment of cognitive function level associated with age-related hearing loss.

Zhao R, Yue T, Xu Z, Zhang Y, Wu Y, Bai Y Geroscience. 2023; 46(1):431-446.

PMID: 37273160 PMC: 10828275. DOI: 10.1007/s11357-023-00847-w.

References
1.
Hoffmann S, Falkenstein M . The correction of eye blink artefacts in the EEG: a comparison of two prominent methods. PLoS One. 2008; 3(8):e3004. PMC: 2500159. DOI: 10.1371/journal.pone.0003004. View

2.
Semlitsch H, Anderer P, Schuster P, Presslich O . A solution for reliable and valid reduction of ocular artifacts, applied to the P300 ERP. Psychophysiology. 1986; 23(6):695-703. DOI: 10.1111/j.1469-8986.1986.tb00696.x. View

3.
Munia T, Haider A, Schneider C, Romanick M, Fazel-Rezai R . A Novel EEG Based Spectral Analysis of Persistent Brain Function Alteration in Athletes with Concussion History. Sci Rep. 2017; 7(1):17221. PMC: 5722818. DOI: 10.1038/s41598-017-17414-x. View

4.
Krupa B, Ali M, Zahedi E . The application of empirical mode decomposition for the enhancement of cardiotocograph signals. Physiol Meas. 2009; 30(8):729-43. DOI: 10.1088/0967-3334/30/8/001. View

5.
Kierkels J, van Boxtel G, Vogten L . A model-based objective evaluation of eye movement correction in EEG recordings. IEEE Trans Biomed Eng. 2006; 53(2):246-53. DOI: 10.1109/TBME.2005.862533. View