» Articles » PMID: 35100106

Estimation of Changes in Intracardiac Hemodynamics Using Wearable Seismocardiography and Machine Learning in Patients With Heart Failure: A Feasibility Study

Overview
Date 2022 Jan 31
PMID 35100106
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Tracking changes in hemodynamic congestion and the consequent proactive readjustment of treatment has shown efficacy in reducing hospitalizations for patients with heart failure (HF). However, the cost-prohibitive nature of these invasive sensing systems precludes their usage in the large patient population affected by HF. The objective of this research is to estimate the changes in pulmonary artery mean pressure (PAM) and pulmonary capillary wedge pressure (PCWP) following vasodilator infusion during right heart catheterization (RHC), using changes in simultaneously recorded wearable seismocardiogram (SCG) signals captured with a small wearable patch.

Methods: A total of 20 patients with HF (20% women, median age 55 (interquartile range (IQR), 44-64) years, ejection fraction 24 (IQR, 16-43)) were fitted with a wearable sensing patch and underwent RHC with vasodilator challenge. We divided the dataset randomly into a training-testing set (n = 15) and a separate validation set (n = 5). We developed globalized (population) regression models to estimate changes in PAM and PCWP from the changes in simultaneously recorded SCG.

Results: The regression model estimated both pressures with good accuracies: root-mean-square-error (RMSE) of 2.5 mmHg and R of 0.83 for estimating changes in PAM, and RMSE of 1.9 mmHg and R of 0.93 for estimating changes in PCWP for the training-testing set, and RMSE of 2.7 mmHg and R of 0.81 for estimating changes in PAM, and RMSE of 2.9 mmHg and R of 0.95 for estimating changes in PCWP for the validation set respectively.

Conclusion: Changes in wearable SCG signals may be used to track acute changes in intracardiac hemodynamics in patients with HF.

Significance: This method holds promise in tracking longitudinal changes in hemodynamic congestion in hemodynamically-guided remote home monitoring and treatment for patients with HF.

Citing Articles

Multifunctional Porous Soft Composites for Bimodal Wearable Cardiac Monitors.

Chen Z, Chen S, Andrabi S, Zhao G, Xu Y, Ouyang Q AIChE J. 2024; 70(12).

PMID: 39713103 PMC: 11661810. DOI: 10.1002/aic.18576.


Noninvasive biometric monitoring technologies for patients with heart failure.

Arriola-Montenegro J, Mutirangura P, Akram H, Tsangaris A, Koukousaki D, Tschida M Heart Fail Rev. 2024; .

PMID: 39436486 DOI: 10.1007/s10741-024-10441-7.


Non-invasive heart failure monitoring: leveraging smart scales and digital biomarkers to improve heart failure outcomes.

Wattanachayakul P, Kittipibul V, Salah H, Yaku H, Nunez J, de la Espriella R Heart Fail Rev. 2024; 29(5):1145-1156.

PMID: 39039364 DOI: 10.1007/s10741-024-10426-6.


Accurate Modeling of Ejection Fraction and Stroke Volume With Mobile Phone Auscultation: Prospective Case-Control Study.

Huecker M, Schutzman C, French J, El-Kersh K, Ghafghazi S, Desai R JMIR Cardio. 2024; 8:e57111.

PMID: 38924781 PMC: 11237790. DOI: 10.2196/57111.


A Wavelet-Based Approach for Motion Artifact Reduction in Ambulatory Seismocardiography.

Skoric J, DMello Y, Plant D IEEE J Transl Eng Health Med. 2024; 12:348-358.

PMID: 38606390 PMC: 11008810. DOI: 10.1109/JTEHM.2024.3368291.


References
1.
Etemadi M, Inan O, Heller J, Hersek S, Klein L, Roy S . A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables. IEEE Trans Biomed Circuits Syst. 2015; 10(2):280-8. PMC: 4643430. DOI: 10.1109/TBCAS.2015.2405480. View

2.
Yang C, Ojha B, Aranoff N, Green P, Tavassolian N . Classification of Aortic Stenosis Before and After Transcatheter Aortic Valve Replacement Using Cardio-mechanical Modalities. Annu Int Conf IEEE Eng Med Biol Soc. 2020; 2020:2820-2823. DOI: 10.1109/EMBC44109.2020.9176321. View

3.
Shandhi M, Semiz B, Hersek S, Goller N, Ayazi F, Inan O . Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation. IEEE J Biomed Health Inform. 2019; 23(6):2365-2374. PMC: 6874489. DOI: 10.1109/JBHI.2019.2895775. View

4.
Hassan S, Turner P . Systolic time intervals: a review of the method in the non-invasive investigation of cardiac function in health, disease and clinical pharmacology. Postgrad Med J. 1983; 59(693):423-34. PMC: 2417541. DOI: 10.1136/pgmj.59.693.423. View

5.
Abraham W, Stevenson L, Bourge R, Lindenfeld J, Bauman J, Adamson P . Sustained efficacy of pulmonary artery pressure to guide adjustment of chronic heart failure therapy: complete follow-up results from the CHAMPION randomised trial. Lancet. 2015; 387(10017):453-61. DOI: 10.1016/S0140-6736(15)00723-0. View