» Articles » PMID: 35079459

Delayed Occlusion of the Anterior Choroidal Artery Following Flow Diverter Stent Deployment for Unruptured Aneurysm: A Case Report and Literature Review

Overview
Journal NMC Case Rep J
Specialty Neurology
Date 2022 Jan 26
PMID 35079459
Authors
Affiliations
Soon will be listed here.
Abstract

Flow diverter stent has been a promising device for intracranial aneurysm treatment. For treating aneurysms located in the anterior circulation, critical branches may be covered by flow diverter stent. The occlusion incidence of these branches has been reported, and even if branch vessel occlusions occur, associated neurological deficits are extremely rare. We present a 55-year-old woman who had a large saccular aneurysm at the right internal carotid artery (ICA). A developed fetal-type posterior communicating artery (PCOM) originated from the sac. We administered flow diverter stent deployment with coil insertion following surgical anastomosis of the superficial temporal artery to the posterior cerebral artery (STA-PCA) with ligation of the origin of the PCOM. On the seventh morning following the intervention, ischemic complication developed due to anterior choroidal artery occlusion jailed by the flow diverter stent. The occlusion of anterior choroidal artery covered by flow diverter stent is extremely rare. However, if the branch arises from the aneurysm sac, occlusion can transpire and induce serious complication. The most probable cause of occlusion in this case was that the orifice was jailed apart from the stent strut because the branch originated from the sac rather than the neck. Furthermore, the progression rate of intra-aneurysm thrombus formation is also an important factor affecting the side branch occlusion.

Citing Articles

A vertebrobasilar junction aneurysm successfully treated with a combination of surgical clipping and flow diverter placement based on the results of computational fluid dynamics analysis: illustrative case.

Mori T, Kimura H, Fujita A, Hayashi K, Hori T, Sugihara M J Neurosurg Case Lessons. 2024; 7(10).

PMID: 38437674 PMC: 10916842. DOI: 10.3171/CASE23736.


Paraclinoid internal carotid artery aneurysm with delayed stent occlusion after deployment of a flow diverter stent involving the orifice of the anterior cerebral artery: illustrative case.

Imai T, Shimizu T, Yamamoto Y, Shimauchi-Ohtaki H, Shintoku R, Aishima K J Neurosurg Case Lessons. 2023; 6(14).

PMID: 37782959 PMC: 10555604. DOI: 10.3171/CASE23290.

References
1.
Becske T, Potts M, Shapiro M, Kallmes D, Brinjikji W, Saatci I . Pipeline for uncoilable or failed aneurysms: 3-year follow-up results. J Neurosurg. 2016; 127(1):81-88. DOI: 10.3171/2015.6.JNS15311. View

2.
Gascou G, Lobotesis K, Brunel H, Machi P, Riquelme C, Eker O . Extra-aneurysmal flow modification following pipeline embolization device implantation: focus on regional branches, perforators, and the parent vessel. AJNR Am J Neuroradiol. 2014; 36(4):725-31. PMC: 7964318. DOI: 10.3174/ajnr.A4191. View

3.
Cagnazzo F, Lefevre P, Mantilla D, Rouchaud A, Morganti R, Perrini P . Patency of the supraclinoid internal carotid artery branches after flow diversion treatment. A meta-analysis. J Neuroradiol. 2018; 46(1):9-14. DOI: 10.1016/j.neurad.2018.07.006. View

4.
Durst C, Starke R, Clopton D, Hixson H, Schmitt P, Gingras J . Endovascular treatment of ophthalmic artery aneurysms: ophthalmic artery patency following flow diversion versus coil embolization. J Neurointerv Surg. 2015; 8(9):919-22. DOI: 10.1136/neurintsurg-2015-011887. View

5.
Becske T, Brinjikji W, Potts M, Kallmes D, Shapiro M, Moran C . Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial. Neurosurgery. 2017; 80(1):40-48. DOI: 10.1093/neuros/nyw014. View