» Articles » PMID: 35069096

Assessing the Effect of the Refresh Rate of a Device on Various Motion Stimulation Frequencies Based on Steady-State Motion Visual Evoked Potentials

Overview
Journal Front Neurosci
Date 2022 Jan 24
PMID 35069096
Authors
Affiliations
Soon will be listed here.
Abstract

The refresh rate is one of the important parameters of visual presentation devices, and assessing the effect of the refresh rate of a device on motion perception has always been an important direction in the field of visual research. This study examined the effect of the refresh rate of a device on the motion perception response at different stimulation frequencies and provided an objective visual electrophysiological assessment method for the correct selection of display parameters in a visual perception experiment. In this study, a flicker-free steady-state motion visual stimulation with continuous scanning frequency and different forms (sinusoidal or triangular) was presented on a low-latency LCD monitor at different refresh rates. Seventeen participants were asked to observe the visual stimulation without head movement or eye movement, and the effect of the refresh rate was assessed by analyzing the changes in the intensity of their visual evoked potentials. The results demonstrated that an increased refresh rate significantly improved the intensity of motion visual evoked potentials at stimulation frequency ranges of 7-28 Hz, and there was a significant interaction between the refresh rate and motion frequency. Furthermore, the increased refresh rate also had the potential to enhance the ability to perceive similar motion. Therefore, we recommended using a refresh rate of at least 120 Hz in motion visual perception experiments to ensure a better stimulation effect. If the motion frequency or velocity is high, a refresh rate of≥240 Hz is also recommended.

Citing Articles

A subjective and objective fusion visual fatigue assessment system for different hardware and software parameters in SSVEP-based BCI applications.

Tian P, Xu G, Han C, Du C, Li H, Chen R Sci Rep. 2024; 14(1):27872.

PMID: 39537730 PMC: 11560949. DOI: 10.1038/s41598-024-79401-3.


Visual Quality, Motility Behavior, and Retinal Changes Associated with Reading Tasks Performed on Electronic Devices.

Orduna-Hospital E, Munarriz-Escribano M, Sanchez-Cano A Life (Basel). 2023; 13(8).

PMID: 37629634 PMC: 10455831. DOI: 10.3390/life13081777.


Questionnaires based on natural language processing elicit immersive ruminative thinking in ruminators: Evidence from behavioral responses and EEG data.

Li Y, Li C, Zhang T, Wu L, Lin X, Li Y Front Neurosci. 2023; 17:1118650.

PMID: 36950128 PMC: 10025410. DOI: 10.3389/fnins.2023.1118650.

References
1.
Nagel S, Dreher W, Rosenstiel W, Spuler M . The effect of monitor raster latency on VEPs, ERPs and Brain-Computer Interface performance. J Neurosci Methods. 2017; 295:45-50. DOI: 10.1016/j.jneumeth.2017.11.018. View

2.
Bognar A, Csibri P, Andras C, Sary G . LCD Monitors as an Alternative for Precision Demanding Visual Psychophysical Experiments. Perception. 2016; 45(9):1070-83. DOI: 10.1177/0301006616651954. View

3.
Born R, Bradley D . Structure and function of visual area MT. Annu Rev Neurosci. 2005; 28:157-89. DOI: 10.1146/annurev.neuro.26.041002.131052. View

4.
Heinrich S, Bach M . Adaptation characteristics of steady-state motion visual evoked potentials. Clin Neurophysiol. 2003; 114(7):1359-66. DOI: 10.1016/s1388-2457(03)00088-9. View

5.
Cao T, Wan F, Man Wong C, da Cruz J, Hu Y . Objective evaluation of fatigue by EEG spectral analysis in steady-state visual evoked potential-based brain-computer interfaces. Biomed Eng Online. 2014; 13(1):28. PMC: 3995691. DOI: 10.1186/1475-925X-13-28. View