» Articles » PMID: 35062385

Commercial and Scientific Solutions for Blood Glucose Monitoring-A Review

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2022 Jan 22
PMID 35062385
Authors
Affiliations
Soon will be listed here.
Abstract

Diabetes is a chronic and, according to the state of the art, an incurable disease. Therefore, to treat diabetes, regular blood glucose monitoring is crucial since it is mandatory to mitigate the risk and incidence of hyperglycemia and hypoglycemia. Nowadays, it is common to use blood glucose meters or continuous glucose monitoring via stinging the skin, which is classified as invasive monitoring. In recent decades, non-invasive monitoring has been regarded as a dominant research field. In this paper, electrochemical and electromagnetic non-invasive blood glucose monitoring approaches will be discussed. Thereby, scientific sensor systems are compared to commercial devices by validating the sensor principle and investigating their performance utilizing the Clarke error grid. Additionally, the opportunities to enhance the overall accuracy and stability of non-invasive glucose sensing and even predict blood glucose development to avoid hyperglycemia and hypoglycemia using post-processing and sensor fusion are presented. Overall, the scientific approaches show a comparable accuracy in the Clarke error grid to that of the commercial ones. However, they are in different stages of development and, therefore, need improvement regarding parameter optimization, temperature dependency, or testing with blood under real conditions. Moreover, the size of scientific sensing solutions must be further reduced for a wearable monitoring system.

Citing Articles

Fire up Biosensor Technology to Assess the Vitality of Trees after Wildfires.

Touloupakis E, Calegari Moia I, Zampieri R, Cocozza C, Frassinelli N, Marchi E Biosensors (Basel). 2024; 14(8).

PMID: 39194602 PMC: 11352662. DOI: 10.3390/bios14080373.


Review of Microwave Near-Field Sensing and Imaging Devices in Medical Applications.

Origlia C, Rodriguez-Duarte D, Tobon Vasquez J, Bolomey J, Vipiana F Sensors (Basel). 2024; 24(14).

PMID: 39065913 PMC: 11280878. DOI: 10.3390/s24144515.


Functionalization of Carbon Nanofibers with an Aromatic Diamine: Toward a Simple Electrochemical-Based Sensing Platform for the Selective Sensing of Glucose.

Ferlazzo A, Celesti C, Iannazzo D, Ampelli C, Giusi D, Costantino V ACS Omega. 2024; 9(25):27085-27092.

PMID: 38947806 PMC: 11209887. DOI: 10.1021/acsomega.4c00525.


Differences in Volatile Organic Compounds Between Concussed and Non-concussed Division I Athletes.

Abadie A, McKeag I, Springer D, Hale M, Fernandez J Cureus. 2024; 16(5):e61241.

PMID: 38939283 PMC: 11210574. DOI: 10.7759/cureus.61241.


Photonic Nanochains for Continuous Glucose Monitoring in Physiological Environment.

Shi G, Si L, Cai J, Jiang H, Liu Y, Luo W Nanomaterials (Basel). 2024; 14(11).

PMID: 38869588 PMC: 11174108. DOI: 10.3390/nano14110964.


References
1.
Gabriel S, Lau R, Gabriel C . The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996; 41(11):2251-69. DOI: 10.1088/0031-9155/41/11/002. View

2.
Kim S, Jeon H, Park S, Lee D, Chung E . Tear Glucose Measurement by Reflectance Spectrum of a Nanoparticle Embedded Contact Lens. Sci Rep. 2020; 10(1):8254. PMC: 7237479. DOI: 10.1038/s41598-020-65103-z. View

3.
Parachalil D, McIntyre J, Byrne H . Potential of Raman spectroscopy for the analysis of plasma/serum in the liquid state: recent advances. Anal Bioanal Chem. 2020; 412(9):1993-2007. DOI: 10.1007/s00216-019-02349-1. View

4.
Blum A . Freestyle Libre Glucose Monitoring System. Clin Diabetes. 2018; 36(2):203-204. PMC: 5898159. DOI: 10.2337/cd17-0130. View

5.
Oyer D . The science of hypoglycemia in patients with diabetes. Curr Diabetes Rev. 2013; 9(3):195-208. DOI: 10.2174/15733998113099990059. View