A Potential Screening Index of Corneal Biomechanics in Healthy Subjects, Forme Fruste Keratoconus Patients and Clinical Keratoconus Patients

Overview
Date 2022 Jan 10
PMID 35004638
Authors
Affiliations
Soon will be listed here.
Abstract

This study aims to evaluate the validity of corneal elastic modulus (E) calculated from corneal visualization Scheimpflug technology (Corvis ST) in diagnosing keratoconus (KC) and forme fruste keratoconus (FFKC). Fifty KC patients (50 eyes), 36 FFKC patients (36 eyes, the eyes were without morphological abnormality, while the contralateral eye was diagnosed as clinical keratoconus), and 50 healthy patients (50 eyes) were enrolled and underwent Corvis measurements. We calculated E according to the relation between airpuff force and corneal apical displacement. One-way analysis of variance (ANOVA) and receiver operating characteristic (ROC) curve analysis were used to identify the predictive accuracy of the E and other dynamic corneal response (DCR) parameters. Besides, we used backpropagation (BP) neural network to establish the keratoconus diagnosis model. 1) There was significant difference between KC and healthy subjects in the following DCR parameters: the first/second applanation time (A1T/A2T), velocity at first/second applanation (A1V/A2V), the highest concavity time (HCT), peak distance (PD), deformation amplitude (DA), Ambrosio relational thickness to the horizontal profile (ARTh). 2) A1T and E were smaller in FFKC and KC compared with healthy subjects. 3) ROC analysis showed that E (AUC = 0.746) was more accurate than other DCR parameters in detecting FFKC (AUC of these DCR parameters was not more than 0.719). 4) Keratoconus diagnosis model by BP neural network showed a more accurate diagnostic efficiency of 92.5%. The ROC analysis showed that the predicted value (AUC = 0.877) of BP neural network model was more sensitive in the detection FFKC than the Corvis built-in parameters CBI (AUC = 0.610, = 0.041) and TBI (AUC = 0.659, = 0.034). Corneal elastic modulus was found to have improved predictability in detecting FFKC patients from healthy subjects and may be used as an additional parameter for the diagnosis of keratoconus.

Citing Articles

Influence of Dextran Solution and Corneal Collagen Crosslinking on Corneal Biomechanical Parameters Evaluated by Corvis ST In Vitro.

Qin X, Hu B, Guo L, Zhang H, Li L, Jie Y Bioengineering (Basel). 2024; 11(11).

PMID: 39593816 PMC: 11592382. DOI: 10.3390/bioengineering11111156.


Keratoconus Diagnosis and Treatment: Recent Advances and Future Directions.

Bui A, Truong A, Pasricha N, Indaram M Clin Ophthalmol. 2023; 17:2705-2718.

PMID: 37736107 PMC: 10511017. DOI: 10.2147/OPTH.S392665.


Quantitative Assessment of Biomechanical Properties of the Human Keratoconus Cornea Using Acoustic Radiation Force Optical Coherence Elastography.

Zhao Y, Yang H, Li Y, Wang Y, Han X, Zhu Y Transl Vis Sci Technol. 2022; 11(6):4.

PMID: 35666497 PMC: 9185997. DOI: 10.1167/tvst.11.6.4.

References
1.
Herber R, Ramm L, Spoerl E, Raiskup F, Pillunat L, Terai N . Assessment of corneal biomechanical parameters in healthy and keratoconic eyes using dynamic bidirectional applanation device and dynamic Scheimpflug analyzer. J Cataract Refract Surg. 2019; 45(6):778-788. DOI: 10.1016/j.jcrs.2018.12.015. View

2.
Ahearne M, Yang Y, Then K, Liu K . An indentation technique to characterize the mechanical and viscoelastic properties of human and porcine corneas. Ann Biomed Eng. 2007; 35(9):1608-16. DOI: 10.1007/s10439-007-9323-9. View

3.
Elsheikh A, Alhasso D, Rama P . Biomechanical properties of human and porcine corneas. Exp Eye Res. 2008; 86(5):783-90. DOI: 10.1016/j.exer.2008.02.006. View

4.
Shen Y, Han T, Jhanji V, Shang J, Zhao J, Li M . Correlation Between Corneal Topographic, Densitometry, and Biomechanical Parameters in Keratoconus Eyes. Transl Vis Sci Technol. 2019; 8(3):12. PMC: 6504131. DOI: 10.1167/tvst.8.3.12. View

5.
Randleman J, Woodward M, Lynn M, Stulting R . Risk assessment for ectasia after corneal refractive surgery. Ophthalmology. 2007; 115(1):37-50. DOI: 10.1016/j.ophtha.2007.03.073. View