» Articles » PMID: 34961570

Assessing Data Accuracy in a Large Multi-institutional Quality Improvement Registry: an Update from the Pediatric Cardiac Critical Care Consortium (PC)

Overview
Journal Cardiol Young
Date 2021 Dec 28
PMID 34961570
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The Pediatric Cardiac Critical Care Consortium (PC) is a multi-institutional quality improvement registry focused on the care delivered in the cardiac ICU for patients with CHD and acquired heart disease. To assess data quality, a rigorous procedure of data auditing has been in place since the inception of the consortium.

Materials And Methods: This report describes the data auditing process and quantifies the audit results for the initial 39 audits that took place after the transition from version one to version two of the registry's database.

Results: In total, 2219 total encounters were audited for an average of 57 encounters per site. The overall data accuracy rate across all sites was 99.4%, with a major discrepancy rate of 0.52%. A passing score is based on an overall accuracy of >97% (achieved by all sites) and a major discrepancy rate of <1.5% (achieved by 38 of 39 sites, with 35 of 39 sites having a major discrepancy rate of <1%). Fields with the highest discrepancy rates included arrhythmia type, cardiac arrest count, and current surgical status.

Conclusions: The extensive PC auditing process, including initial and routinely scheduled follow-up audits of every participating site, demonstrates an extremely high level of accuracy across a broad array of audited fields and supports the continued use of consortium data to identify best practices in paediatric cardiac critical care.

Citing Articles

Sustained Performance of Cardiac Arrest Prevention in Pediatric Cardiac Intensive Care Units.

Mueller D, Bailly D, Banerjee M, Bertrandt R, Borasino S, Briceno-Medina M JAMA Netw Open. 2024; 7(9):e2432393.

PMID: 39250152 PMC: 11385048. DOI: 10.1001/jamanetworkopen.2024.32393.


An evaluation of the outcomes associated with peritoneal catheter use in neonates undergoing cardiac surgery: A multicenter study.

Kwiatkowski D, Alten J, Mah K, Selewski D, Raymond T, Afonso N JTCVS Open. 2024; 19:275-295.

PMID: 39015443 PMC: 11247230. DOI: 10.1016/j.xjon.2024.03.009.


Racial and Ethnic Variation in ECMO Utilization and Outcomes in Pediatric Cardiac ICU Patients.

Brunetti M, Griffis H, OByrne M, Glatz A, Huang J, Schumacher K JACC Adv. 2024; 2(9):100634.

PMID: 38938717 PMC: 11198441. DOI: 10.1016/j.jacadv.2023.100634.


Diuretic response after neonatal cardiac surgery: a report from the NEPHRON collaborative.

Blinder J, Alten J, Bailly D, Buckley J, Clarke S, Wesley Diddle J Pediatr Nephrol. 2024; 39(9):2797-2805.

PMID: 38713228 DOI: 10.1007/s00467-024-06380-y.


Factors Associated With Attendance for Cardiac Neurodevelopmental Evaluation.

Ortinau C, Wypij D, Ilardi D, Rofeberg V, Miller T, Donohue J Pediatrics. 2023; 152(3).

PMID: 37593818 PMC: 10530086. DOI: 10.1542/peds.2022-060995.