Abstract

The diversity of materials proposed for non-enzymatic glucose detection and the lack of standardized protocols for assessing sensor performance have caused considerable confusion in the field. Therefore, methods for pre-evaluation of working electrodes, which will enable their conscious design, are currently intensively sought. Our approach involved comprehensive morphologic and structural characterization of copper sulfides as well as drop-casted suspensions based on three different polymers-cationic chitosan, anionic Nafion, and nonionic polyvinylpyrrolidone (PVP). For this purpose, scanning electron microscopy (SEM), X-ray diffraction (XRD), and Raman spectroscopy were applied. Subsequently, comparative studies of electrochemical properties of bare glassy carbon electrode (GCE), polymer- and copper sulfides/polymer-modified GCEs were performed using electrochemical impedance spectroscopy (EIS) and voltammetry. The results from EIS provided an explanation for the enhanced analytical performance of Cu-PVP/GCE over chitosan- and Nafion-based electrodes. Moreover, it was found that the pH of the electrolyte significantly affects the electrocatalytic behavior of copper sulfides, indicating the importance of OH in the detection mechanism. Additionally, diffusion was denoted as a limiting step in the irreversible electrooxidation process that occurs in the proposed system.

Citing Articles

Comparative Study of Polymer-Modified Copper Oxide Electrochemical Sensors: Stability and Performance Analysis.

Baziak A, Kusior A Sensors (Basel). 2024; 24(16).

PMID: 39204984 PMC: 11359257. DOI: 10.3390/s24165290.


Simple Fluorescence Sensing Approach for Selective Detection of Fe Ions: Live-Cell Imaging and Logic Gate Functioning.

Rasin P, Manakkadan V, Vadakkedathu Palakkeezhillam V, Haribabu J, Echeverria C, Sreekanth A ACS Omega. 2022; 7(37):33248-33257.

PMID: 36157778 PMC: 9494683. DOI: 10.1021/acsomega.2c03718.

References
1.
Cruz J, Kawasaki M, Gorski W . Electrode coatings based on chitosan scaffolds. Anal Chem. 2000; 72(4):680-6. DOI: 10.1021/ac990954b. View

2.
TAYLOR L, Langkilde F, Zografi G . Fourier transform Raman spectroscopic study of the interaction of water vapor with amorphous polymers. J Pharm Sci. 2001; 90(7):888-901. DOI: 10.1002/jps.1041. View

3.
Hassan M, Vyas C, Grieve B, Bartolo P . Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing. Sensors (Basel). 2021; 21(14). PMC: 8309655. DOI: 10.3390/s21144672. View

4.
Keerthi M, Mutharani B, Chen S, Ranganathan P . Carbon fibers coated with urchin-like copper sulfide for nonenzymatic voltammetric sensing of glucose. Mikrochim Acta. 2019; 186(12):807. DOI: 10.1007/s00604-019-3915-6. View

5.
Chelaghmia M, Fisli H, Nacef M, Brownson D, Affoune A, Satha H . Disposable non-enzymatic electrochemical glucose sensors based on screen-printed graphite macroelectrodes modified via a facile methodology with Ni, Cu, and Ni/Cu hydroxides are shown to accurately determine glucose in real human serum blood samples. Anal Methods. 2021; 13(25):2812-2822. DOI: 10.1039/d1ay00056j. View