» Articles » PMID: 34840631

Association Between Iris Biological Features and Corneal Biomechanics in Myopic Eyes

Overview
Journal Dis Markers
Publisher Wiley
Specialty Biochemistry
Date 2021 Nov 29
PMID 34840631
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Iris biological features such as surface features and profile characteristics reflected the development of iris stroma and microvessels. Iris vessels and microcirculation are still lack of effective detection methods, and we can directly observe only the iris surface biological characteristics. This cross-sectional study evaluated the association between iris surface biological features and corneal biomechanics in young adults with myopia.

Methods: We recruited 152 patients with myopia aged ≥18 years, from the Eye Hospital of Wenzhou Medical University, who had complete Corneal Visualization Scheimpflug Technology (Corvis ST) data and graded iris surface features. Iris surface features included crypts, furrows, and color measured from digital slit lamp images. The biomechanical properties of the cornea were assessed using Corvis ST. Only 1 eye of each participant was randomly selected for analysis. Associations between the iris surface features and corneal biomechanics were analyzed using linear regression models. The grade of iris crypts, furrows, and color and corneal biomechanical parameters measured with Corvis ST was the main outcome measures.

Results: The iris crypts were significantly associated with deflection amplitude at the first applanation (A1 DLA, = 0.001, = 0.013), A1 delta arc length (A1 dArcL) ( = -0.001, = 0.01), maximum delta arc length (dArcLM) ( = -0.004, = 0.03), and stiffness at the first applanation (SP-A1) ( = -2.092, = 0.016). The iris furrows were only associated with integrated radius ( = -0.212, = 0.025). Iris color was found not related with corneal biomechanical parameters measured via Corvis ST.

Conclusions: Iris surface features were associated with corneal biomechanical properties in myopic eyes; more iris crypts were associated with lower corneal stiffness while more extensive furrows were related with higher corneal stiffness. Iris crypts and furrows may provide useful information on corneal biomechanical properties in myopic eyes.

Citing Articles

Corneal Biomechanical Properties Demonstrate Anisotropy and Correlate With Axial Length in Myopic Eyes.

Chen L, Huang Y, Zhang X, Shi Y, Gao Z, Sun B Invest Ophthalmol Vis Sci. 2023; 64(10):27.

PMID: 37477932 PMC: 10365135. DOI: 10.1167/iovs.64.10.27.


Association of Iris Structural Measurements with Corneal Biomechanics in Myopic Eyes.

Fu L, Ye Y, Jia X, Zhang Y, Chen X, Lian H Dis Markers. 2022; 2021:2080962.

PMID: 35003388 PMC: 8741339. DOI: 10.1155/2021/2080962.

References
1.
Pant A, Gogte P, Pathak-Ray V, Dorairaj S, Amini R . Increased Iris Stiffness in Patients With a History of Angle-Closure Glaucoma: An Image-Based Inverse Modeling Analysis. Invest Ophthalmol Vis Sci. 2018; 59(10):4134-4142. DOI: 10.1167/iovs.18-24327. View

2.
Chua J, Thakku S, Tun T, Nongpiur M, Tan M, Girard M . Iris Crypts Influence Dynamic Changes of Iris Volume. Ophthalmology. 2016; 123(10):2077-84. DOI: 10.1016/j.ophtha.2016.06.034. View

3.
Jung Y, Chun H, Moon J . Corneal deflection amplitude and visual field progression in primary open-angle glaucoma. PLoS One. 2019; 14(8):e0220655. PMC: 6690643. DOI: 10.1371/journal.pone.0220655. View

4.
Edwards M, Cha D, Krithika S, Johnson M, Parra E . Analysis of iris surface features in populations of diverse ancestry. R Soc Open Sci. 2016; 3(1):150424. PMC: 4736923. DOI: 10.1098/rsos.150424. View

5.
Sidhartha E, Gupta P, Liao J, Tham Y, Cheung C, He M . Assessment of iris surface features and their relationship with iris thickness in Asian eyes. Ophthalmology. 2014; 121(5):1007-12. DOI: 10.1016/j.ophtha.2013.11.028. View