Explaining the Adoption and Use of Computed Tomography and Magnetic Resonance Image Technologies in Public Hospitals

Overview
Publisher Biomed Central
Specialty Health Services
Date 2021 Nov 28
PMID 34838015
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: This article examines what the adoption and use of advanced medical technologies - computed tomography (CT) and magnetic resonance imaging (MRI) - by public hospitals depend on and to what extent.

Methods: From a sample of panel data for all public hospitals in the health service of Galicia (a subregion of the Galicia-North of Portugal Euroregion) for the 2010-2017 period, we grouped explanatory variables into inputs (resources), outputs (activities) and socio-demographic variables. Factor analysis was used to reduce as much as possible the number of analysed variables, discriminant analysis to examine the technologies adoption decision, and multiple regression analysis to investigate their use.

Results: Factor analysis identified motivators on adoption and use of CT and MRI medical technologies as follows: hospital inputs/outputs (Factor 1); radiology studies and adoption of CT by public hospitals (Factor 2); research/teaching role and big-ticket diagnostic and therapeutic (lithotripsy) technologies (Factor 3); number of transplants (Factor 4); cancer diagnosis/treatment (Factor 5); and catchment area geographical dispersion (Factor 6). Cronbach's alpha of 0.881 indicated an acceptable degree of reliability of the factor variables. Regarding adoption of these technologies, Factor 1 is the most influential, explaining 37% of the variance and showing adequate global internal consistency, whereas Factor 2 is limited to 13% of the variance. In the discriminant analysis, values for Box's M test and canonical correlations such as Wilks's lambda for the two technologies underpin the reliability and predictive capacity of the discriminant equations. Finally, and according to the regression analysis, the factor with the greatest influence on CT and MRI use is Factor 2, followed by Factors 1 and 3 in the case of CT use, and Factors 3 and 5 in the case of MRI use.

Conclusion: CT and MRI adoption by public hospitals is mainly determined by hospital inputs and outputs. However, the use of both medical technologies is mainly influenced by conventional radiology studies and CT adoption. These results suggest that both choices - adoption and use of advanced medical technology - may be separate decisions as they are taken possibly by different people (the former by managers and policymakers and the latter by physicians).

Citing Articles

Cost Analysis of Magnetic Resonance Imaging and Computed Tomography in Cardiology: A Case Study of a University Hospital Complex in the Euro Region.

Reyes-Santias F, Garcia-Garcia C, Aibar-Guzman B, Garcia-Campos A, Cordova-Arevalo O, Mendoza-Pintos M Healthcare (Basel). 2023; 11(14).

PMID: 37510526 PMC: 10379578. DOI: 10.3390/healthcare11142084.


Analysis and Forecast of Indicators Related to Medical Workers and Medical Technology in Selected Countries of Eastern Europe and Balkan.

Stepovic M, Vekic S, Vojinovic R, Jovanovic K, Radovanovic S, Radevic S Healthcare (Basel). 2023; 11(5).

PMID: 36900660 PMC: 10000486. DOI: 10.3390/healthcare11050655.

References
1.
Neumann P, Cohen J, Weinstein M . Updating cost-effectiveness--the curious resilience of the $50,000-per-QALY threshold. N Engl J Med. 2014; 371(9):796-7. DOI: 10.1056/NEJMp1405158. View

2.
Lee R, Waldman D . The diffusion of innovations in hospitals. Some econometric considerations. J Health Econ. 1985; 4(4):373-80. DOI: 10.1016/0167-6296(85)90014-1. View

3.
McGregor M . Technology and the allocation of resources. N Engl J Med. 1989; 320(2):118-20. DOI: 10.1056/NEJM198901123200209. View

4.
Abedini Z, Akbari Sari A, Rahimi Foroushani A, Jaafaripooyan E . Diffusion of advanced medical imaging technology, CT, and MRI scanners, in Iran: A qualitative study of determinants. Int J Health Plann Manage. 2018; 34(1):e397-e410. DOI: 10.1002/hpm.2657. View

5.
Niki R . The wide distribution of CT scanners in Japan. Soc Sci Med. 1985; 21(10):1131-7. DOI: 10.1016/0277-9536(85)90171-6. View