» Articles » PMID: 34834002

Nontargeted Screening Using Gas Chromatography-Atmospheric Pressure Ionization Mass Spectrometry: Recent Trends and Emerging Potential

Overview
Journal Molecules
Publisher MDPI
Specialty Biology
Date 2021 Nov 27
PMID 34834002
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Gas chromatography-high-resolution mass spectrometry (GC-HRMS) is a powerful nontargeted screening technique that promises to accelerate the identification of environmental pollutants. Currently, most GC-HRMS instruments are equipped with electron ionization (EI), but atmospheric pressure ionization (API) ion sources have attracted renewed interest because: (i) collisional cooling at atmospheric pressure minimizes fragmentation, resulting in an increased yield of molecular ions for elemental composition determination and improved detection limits; (ii) a wide range of sophisticated tandem (ion mobility) mass spectrometers can be easily adapted for operation with GC-API; and (iii) the conditions of an atmospheric pressure ion source can promote structure diagnostic ion-molecule reactions that are otherwise difficult to perform using conventional GC-MS instrumentation. This literature review addresses the merits of GC-API for nontargeted screening while summarizing recent applications using various GC-API techniques. One perceived drawback of GC-API is the paucity of spectral libraries that can be used to guide structure elucidation. Herein, novel data acquisition, deconvolution and spectral prediction tools will be reviewed. With continued development, it is anticipated that API may eventually supplant EI as the de facto GC-MS ion source used to identify unknowns.

Citing Articles

High-Resolution Mass Spectrometry for Human Exposomics: Expanding Chemical Space Coverage.

Lai Y, Koelmel J, Walker D, Price E, Papazian S, Manz K Environ Sci Technol. 2024; 58(29):12784-12822.

PMID: 38984754 PMC: 11271014. DOI: 10.1021/acs.est.4c01156.


Spotlight on mass spectrometric non-target screening analysis: Advanced data processing methods recently communicated for extracting, prioritizing and quantifying features.

Minkus S, Bieber S, Letzel T Anal Sci Adv. 2024; 3(3-4):103-112.

PMID: 38715638 PMC: 10989605. DOI: 10.1002/ansa.202200001.


Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile.

Ayala-Cabrera J, Montero L, Sahlabji T, Schmitz O Anal Bioanal Chem. 2023; 415(13):2561-2573.

PMID: 37059842 PMC: 10149472. DOI: 10.1007/s00216-023-04688-6.


First Novel Workflow for Semiquantification of Emerging Contaminants in Environmental Samples Analyzed by Gas Chromatography-Atmospheric Pressure Chemical Ionization-Quadrupole Time of Flight-Mass Spectrometry.

Aalizadeh R, Nikolopoulou V, Alygizakis N, Thomaidis N Anal Chem. 2022; 94(27):9766-9774.

PMID: 35760399 PMC: 9280717. DOI: 10.1021/acs.analchem.2c01432.


Benefits of Ion Mobility Separation in GC-APCI-HRMS Screening: From the Construction of a CCS Library to the Application to Real-World Samples.

Izquierdo-Sandoval D, Fabregat-Safont D, Lacalle-Bergeron L, Sancho J, Hernandez F, Portoles T Anal Chem. 2022; 94(25):9040-9047.

PMID: 35696365 PMC: 9974067. DOI: 10.1021/acs.analchem.2c01118.


References
1.
Richter-Brockmann S, Dettbarn G, Jessel S, John A, Seidel A, Achten C . GC-APLI-MS as a powerful tool for the analysis of BaP-tetraol in human urine. J Chromatogr B Analyt Technol Biomed Life Sci. 2018; 1100-1101:1-5. DOI: 10.1016/j.jchromb.2018.08.006. View

2.
Grosse Brinkhaus S, Thianer J, Achten C . Ultra-high sensitive PAH analysis of certified reference materials and environmental samples by GC-APLI-MS. Anal Bioanal Chem. 2017; 409(11):2801-2812. DOI: 10.1007/s00216-017-0224-y. View

3.
Koopman J, Grimme S . From QCEIMS to QCxMS: A Tool to Routinely Calculate CID Mass Spectra Using Molecular Dynamics. J Am Soc Mass Spectrom. 2021; 32(7):1735-1751. DOI: 10.1021/jasms.1c00098. View

4.
Li X, Zhen Y, Wang R, Li T, Dong S, Zhang W . Application of gas chromatography coupled to triple quadrupole mass spectrometry (GC-(APCI)MS/MS) in determination of PCBs (mono-to deca-) and PCDD/Fs in Chinese mitten crab food webs. Chemosphere. 2020; 265:129055. DOI: 10.1016/j.chemosphere.2020.129055. View

5.
Li D, Gan L, Bronja A, Schmitz O . Gas chromatography coupled to atmospheric pressure ionization mass spectrometry (GC-API-MS): review. Anal Chim Acta. 2015; 891:43-61. DOI: 10.1016/j.aca.2015.08.002. View