» Articles » PMID: 3479905

Surface Interactions on Hydrogel Extended Wear Contact Lenses: Microflora and Microfauna

Overview
Specialty Ophthalmology
Date 1987 Oct 1
PMID 3479905
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The microbial flora and fauna of 25 high water content nonionic "soft" contact lenses worn by patients on an extended wear basis, 4 hand-cleaned patient-worn lenses, and 4 improperly maintained lenses were compared. Almost all the patient-worn lenses (24 of 25) were free of viable microorganisms, whereas all the hand-cleaned lenses (4 of 4) were contaminated with different microorganisms. This study showed that hand contact is a major source of microbial contamination of a lens and that usually the hand-transported microorganisms do not survive permanently on the lens in a healthy, normal eye. Improperly maintained lenses demonstrated pathogenic microbial associations. Proof of the eye's potent antimicrobial environment was demonstrated. Thus, microorganism-lens associations are largely due to lens handling and inappropriate maintenance regimens. Typically there are few microorganisms on an extended wear soft lens while it is being worn.

Citing Articles

Microbial contamination of contact lenses, lens care solutions, and their accessories: a literature review.

Szczotka-Flynn L, Pearlman E, Ghannoum M Eye Contact Lens. 2010; 36(2):116-29.

PMID: 20168237 PMC: 3482476. DOI: 10.1097/ICL.0b013e3181d20cae.


Risk factors for contact lens bacterial contamination during continuous wear.

Szczotka-Flynn L, Bajaksouzian S, Jacobs M, Rimm A Optom Vis Sci. 2009; 86(11):1216-26.

PMID: 19786927 PMC: 2783769. DOI: 10.1097/OPX.0b013e3181bbca18.


Haemophilus influenzae adherent to contact lenses associated with production of acute ocular inflammation.

Sankaridurg P, Willcox M, Sharma S, Gopinathan U, Janakiraman D, Hickson S J Clin Microbiol. 1996; 34(10):2426-31.

PMID: 8880493 PMC: 229286. DOI: 10.1128/jcm.34.10.2426-2431.1996.


Bacterial adhesion measurements on soft contact lenses using a Modified Vortex Device and a Modified Robbins Device.

Schultz C, Pezzutti M, Silor D, White R J Ind Microbiol. 1995; 15(3):243-7.

PMID: 8519483 DOI: 10.1007/BF01569831.


Changes to the ocular biota with time in extended- and daily-wear disposable contact lens use.

Stapleton F, Willcox M, Fleming C, Hickson S, Sweeney D, Holden B Infect Immun. 1995; 63(11):4501-5.

PMID: 7591092 PMC: 173641. DOI: 10.1128/iai.63.11.4501-4505.1995.