» Articles » PMID: 34768500

Ultrasound Cyclo Plasty for Treatment of Surgery-Naïve Open-Angle Glaucoma Patients: A Prospective, Multicenter, 2-Year Follow-Up Trial

Overview
Journal J Clin Med
Specialty General Medicine
Date 2021 Nov 13
PMID 34768500
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The purpose of this prospective study was to evaluate the efficacy and safety of the Ultrasound Cyclo Plasty (UCP) procedure using high-intensity focused ultrasound in surgery-naïve open-angle glaucoma patients.

Methods: prospective, non-randomized, single-arm, multicenter clinical trial. Sixty-six eyes with primary open-angle glaucoma, intraocular pressure (IOP) ≥21 mmHg and with no history of filtering surgery were enrolled. Patients were treated by UCP with a therapy probe comprising six piezoelectric transducers, consecutively activated for 8 s each. Complete ophthalmic examination was performed before the procedure, 1 day after the procedure, and 1, 3, 6, 12, 18 and 24 months after the procedure. Primary outcomes were complete success (defined as IOP lowering from baseline ≥20% without additional glaucoma medications) and vision-threatening complications. Secondary outcomes were the presence of complications and the reduction of the number of medications used.

Results: IOP was significantly reduced after one procedure ( < 0.05), from a mean pre-operative value of 24.3 ± 2.9 mmHg (n = 2.3 hypotensive medications) to a mean value of 15.9 ± 3.6 mmHg (n = 2.2 hypotensive medications) at 2 years (mean IOP lowering of 33%). Surgical success was achieved in 74% of eyes. Notwithstanding side effects such as transient anterior chamber inflammation, refractive error changes, transient hypotony and macular edema, no major intra or post-operative complications such as phthisis, induced cataract, neovascularization or significant vision loss were observed.

Conclusions: Ultrasound Cyclo Plasty is a valuable, effective and well-tolerated procedure to lower IOP in patients with open-angle glaucoma without previous filtering surgery.

Citing Articles

Iris neovascularization and neurotrophic keratopathy following ultrasound cycloplasty in refractory glaucoma: case series.

Chen Z, Wu Y, Yu M BMC Ophthalmol. 2024; 24(1):188.

PMID: 38654174 PMC: 11040811. DOI: 10.1186/s12886-024-03460-3.


Distribution of ultrasound cyclo plasty probe models in Chinese patients with glaucoma.

Zheng S, Wang D, Huang Z, Chen L, Hu H, Hu M Int Ophthalmol. 2023; 43(12):4435-4441.

PMID: 37804368 DOI: 10.1007/s10792-023-02818-8.


Efficacy and safety of ultrasound cycloplasty for the treatment of glaucoma: a Meta-analysis.

Wu T, Yin X, Li J, Lu P Int J Ophthalmol. 2023; 16(8):1317-1325.

PMID: 37602344 PMC: 10398525. DOI: 10.18240/ijo.2023.08.19.


Ultrasound cyclo-plasty for moderate glaucoma: Eighteen-month results from a prospective study.

Wang R, Li N, Chen X Front Med (Lausanne). 2023; 9:1009273.

PMID: 36590936 PMC: 9801481. DOI: 10.3389/fmed.2022.1009273.


Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma.

Chen D, Guo X, Luo S, Lu Y, Tang X BMC Ophthalmol. 2022; 22(1):401.

PMID: 36207670 PMC: 9542456. DOI: 10.1186/s12886-022-02622-5.

References
1.
Aptel F, Tadjine M, Rouland J . Efficacy and Safety of Repeated Ultrasound Cycloplasty Procedures in Patients With Early or Delayed Failure After a First Procedure. J Glaucoma. 2019; 29(1):24-30. DOI: 10.1097/IJG.0000000000001400. View

2.
Kosoko O, Gaasterland D, POLLACK I, Enger C . Long-term outcome of initial ciliary ablation with contact diode laser transscleral cyclophotocoagulation for severe glaucoma. The Diode Laser Ciliary Ablation Study Group. Ophthalmology. 1996; 103(8):1294-302. DOI: 10.1016/s0161-6420(96)30508-3. View

3.
Sousa D, Ferreira N, Marques-Neves C, Somers A, Vandewalle E, Stalmans I . High-intensity Focused Ultrasound Cycloplasty: Analysis of Pupil Dynamics. J Curr Glaucoma Pract. 2019; 12(3):102-106. PMC: 6647825. DOI: 10.5005/jp-journals-10028-1253. View

4.
Aptel F, Denis P, Rouland J, Renard J, Bron A . Multicenter clinical trial of high-intensity focused ultrasound treatment in glaucoma patients without previous filtering surgery. Acta Ophthalmol. 2015; 94(5):e268-77. DOI: 10.1111/aos.12913. View

5.
Sterk C, vd Valk P, van Hees C, van Delft J, Van Best J, Oosterhuis J . The effect of therapeutic ultrasound on the average of multiple intraocular pressures throughout the day in therapy-resistant glaucoma. Graefes Arch Clin Exp Ophthalmol. 1989; 227(1):36-8. DOI: 10.1007/BF02169822. View