» Articles » PMID: 34756077

Prospective Study of the Performance of Parent-Collected Nasal and Saliva Swab Samples, Compared with Nurse-Collected Swab Samples, for the Molecular Detection of Respiratory Microorganisms

Overview
Specialty Microbiology
Date 2021 Nov 10
PMID 34756077
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Respiratory tract infections (RTIs) are ubiquitous among children in the community. A prospective observational study was performed to evaluate the diagnostic performance and quality of at-home parent-collected (PC) nasal and saliva swab samples, compared to nurse-collected (NC) swab samples, from children with RTI symptoms. Children with RTI symptoms were swabbed at home on the same day by a parent and a nurse. We compared the performance of PC swab samples as the test with NC swab samples as the reference for the detection of respiratory pathogen gene targets by reverse transcriptase PCR, with quality assessment using a human gene. PC and NC paired nasal and saliva swab samples were collected from 91 and 92 children, respectively. Performance and interrater agreement (Cohen's κ) of PC versus NC nasal swab samples for viruses combined showed sensitivity of 91.6% (95% confidence interval [CI], 85.47 to 95.73%) and κ of 0.84 (95% CI, 0.79 to 0.88), respectively; the respective values for bacteria combined were 91.4% (95% CI, 86.85 to 94.87%) and κ of 0.85 (95% CI, 0.80 to 0.89). In saliva samples, viral and bacterial sensitivities were lower at 69.0% (95% CI, 57.47 to 79.76%) and 78.1% (95% CI, 71.60 to 83.76%), as were κ values at 0.64 (95% CI, 0.53 to 0.72) and 0.70 (95% CI, 0.65 to 0.76), respectively. Quality assessment for human biological material (18S rRNA) indicated perfect interrater agreement. At-home PC nasal swab samples performed comparably to NC swab samples, whereas PC saliva swab samples lacked sensitivity for the detection of respiratory microbes. RTIs are ubiquitous among children. Diagnosis involves a swab sample being taken by a health professional, which places a considerable burden on community health care systems, given the number of cases involved. The coronavirus disease 2019 (COVID-19) pandemic has seen an increase in the at-home self-collection of upper respiratory tract swab samples without the involvement of health professionals. It is advised that parents conduct or supervise swabbing of children. Surprisingly, few studies have addressed the quality of PC swab samples for subsequent identification of respiratory pathogens. We compared NC and PC nasal and saliva swab samples taken from the same child with RTI symptoms, for detection of respiratory pathogens. The PC nasal swab samples performed comparably to NC samples, whereas saliva swab samples lacked sensitivity for the detection of respiratory microbes. Collection of swab samples by parents would greatly reduce the burden on community nurses without reducing the effectiveness of diagnoses.

Citing Articles

The effect of sample site and collection procedure on identification of SARS-CoV-2 infection.

Davenport C, Arevalo-Rodriguez I, Mateos-Haro M, Berhane S, Dinnes J, Spijker R Cochrane Database Syst Rev. 2024; 12:CD014780.

PMID: 39679851 PMC: 11648846. DOI: 10.1002/14651858.CD014780.


Rapid respiratory microbiological point-of-care-testing and antibiotic prescribing in primary care: Protocol for the RAPID-TEST randomised controlled trial.

Abbs S, Armstrong-Buisseret L, Eastwood K, Granier S, Lane A, Lui M PLoS One. 2024; 19(5):e0302302.

PMID: 38768129 PMC: 11104596. DOI: 10.1371/journal.pone.0302302.


Current State of Genomics in Nursing: A Scoping Review of Healthcare Provider Oriented (Clinical and Educational) Outcomes (2012-2022).

Thomas J, Keels J, Calzone K, Badzek L, Dewell S, Patch C Genes (Basel). 2023; 14(11).

PMID: 38002957 PMC: 10671121. DOI: 10.3390/genes14112013.


Effectiveness of Self-Collected, Ambient Temperature-Preserved Nasal Swabs Compared to Samples Collected by Trained Staff for Genotyping of Respiratory Viruses by Shotgun RNA Sequencing: Comparative Study.

Soto R, Paul L, Porucznik C, Xie H, Stinnett R, Briggs B JMIR Form Res. 2023; 7:e32848.

PMID: 37999952 PMC: 10709791. DOI: 10.2196/32848.


Comparison of Nasal Swabs, Nasopharyngeal Swabs, and Saliva Samples for the Detection of SARS-CoV-2 and other Respiratory Virus Infections.

Jung E, Lee S, Shin S, Kim J, Woo H, Cho E Ann Lab Med. 2023; 43(5):434-442.

PMID: 37080744 PMC: 10151282. DOI: 10.3343/alm.2023.43.5.434.


References
1.
McHugh M . Interrater reliability: the kappa statistic. Biochem Med (Zagreb). 2012; 22(3):276-82. PMC: 3900052. View

2.
McCulloch D, Kim A, Wilcox N, Logue J, Greninger A, Englund J . Comparison of Unsupervised Home Self-collected Midnasal Swabs With Clinician-Collected Nasopharyngeal Swabs for Detection of SARS-CoV-2 Infection. JAMA Netw Open. 2020; 3(7):e2016382. PMC: 7376392. DOI: 10.1001/jamanetworkopen.2020.16382. View

3.
Jones N, Morris A, Curran M, Parmar S, Sule O, Enoch D . Evaluating the use of a 22-pathogen TaqMan array card for rapid diagnosis of respiratory pathogens in intensive care. J Med Microbiol. 2020; 69(7):971-978. DOI: 10.1099/jmm.0.001218. View

4.
Zoch B, Karch A, Dreesman J, Monazahian M, Baillot A, Mikolajczyk R . Feasibility of a birth cohort study dedicated to assessing acute infections using symptom diaries and parental collection of biomaterials. BMC Infect Dis. 2015; 15:436. PMC: 4618955. DOI: 10.1186/s12879-015-1189-0. View

5.
Wehrhahn M, Robson J, Brown S, Bursle E, Byrne S, New D . Self-collection: An appropriate alternative during the SARS-CoV-2 pandemic. J Clin Virol. 2020; 128:104417. PMC: 7198188. DOI: 10.1016/j.jcv.2020.104417. View