» Articles » PMID: 34730862

The Stability of Cerebrovascular CO Reactivity Following Attainment of Physiological Steady-state

Overview
Journal Exp Physiol
Specialty Physiology
Date 2021 Nov 3
PMID 34730862
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

New Findings: What is the central question of this study? During a steady-state cerebrovascular CO reactivity test, do different data extraction time points change the outcome for cerebrovascular CO reactivity? What is the main finding and its importance? Once steady-state end-tidal pressure of CO and haemodynamics were achieved, cerebral blood flow was stable, and so cerebrovascular CO reactivity values remained unchanged regardless of data extraction length (30 vs. 60 s) and time point (at 2-5 min).

Abstract: This study assessed cerebrovascular CO reactivity (CVR) and examined data extraction time points and durations with the hypotheses that: (1) there would be no difference in CVR values when calculated with cerebral blood flow (CBF) measures at different time points following the attainment of physiological steady-state, (2) once steady-state was achieved there would be no difference in CVR values derived from 60 to 30 s extracted means, and (3) that changes in would not be associated with any changes in CVR. We conducted a single step iso-oxic hypercapnic CVR test using dynamic end-tidal forcing (end-tidal , +9.4 ± 0.7 mmHg), and transcranial Doppler and Duplex ultrasound of middle cerebral artery (MCA) and internal carotid artery (ICA), respectively. From the second minute of hypercapnia onwards, physiological steady-state was apparent, with no subsequent changes in end-tidal , or mean arterial pressure. Therefore, CVR measured in the ICA and MCA was stable following the second minute of hypercapnia onwards. Data extraction durations of 30 or 60 s did not give statistically different CVR values. No differences in CVR were detected following the second minute of hypercapnia after accounting for mean arterial pressure via calculated conductance or covariation of mean arterial pressure. These findings demonstrate that, provided the stimulus remains in a steady-state, data extracted from any minute of a CVR test during physiological steady-state conditions produce equivalent CVR values; any change in the CVR value would represent a failure of CVR mechanisms, a change in the magnitude of the stimulus, or measurement error.

Citing Articles

Cool head-out water immersion does not alter cerebrovascular reactivity to hypercapnia despite elevated middle cerebral artery blood velocity: A pilot study.

Worley M, Reed E, Klaes N, Schlader Z, Johnson B PLoS One. 2024; 19(3):e0298587.

PMID: 38478550 PMC: 10936844. DOI: 10.1371/journal.pone.0298587.


The acute influence of amateur boxing on dynamic cerebral autoregulation and cerebrovascular reactivity to carbon dioxide.

Wallis W, Al-Alem Q, Lorimer H, Smail O, Williams G, Bond B Eur J Appl Physiol. 2023; 124(3):993-1003.

PMID: 37768343 PMC: 10879355. DOI: 10.1007/s00421-023-05324-y.


Cerebral blood flow and cerebrovascular reactivity are modified by maturational stage and exercise training status during youth.

Talbot J, Perkins D, Tallon C, Dawkins T, Douglas A, Beckerleg R Exp Physiol. 2023; 108(12):1500-1515.

PMID: 37742137 PMC: 10988468. DOI: 10.1113/EP091279.


Reproducibility and diurnal variation in middle cerebral artery blood velocity in healthy humans.

Shariffi B, Lloyd I, Cessac M, Harper J, Limberg J Exp Physiol. 2023; 108(5):692-705.

PMID: 36951536 PMC: 10148902. DOI: 10.1113/EP090873.


Changes in cerebral autoregulation and vasoreactivity after surgical aortic valve replacement: a prospective study.

Pedro T, Costa A, Ferreira J, Rocha A, Salgueiro E, Pereira G Exp Physiol. 2022; 108(1):103-110.

PMID: 36404590 PMC: 10103757. DOI: 10.1113/EP090502.