» Articles » PMID: 34690689

Sensory Percepts Elicited by Chronic Macro-Sieve Electrode Stimulation of the Rat Sciatic Nerve

Overview
Journal Front Neurosci
Date 2021 Oct 25
PMID 34690689
Authors
Affiliations
Soon will be listed here.
Abstract

Intuitive control of conventional prostheses is hampered by their inability to provide the real-time tactile and proprioceptive feedback of natural sensory pathways. The macro-sieve electrode (MSE) is a candidate interface to amputees' truncated peripheral nerves for introducing sensory feedback from external sensors to facilitate prosthetic control. Its unique geometry enables selective control of the complete nerve cross-section by current steering. Unlike previously studied interfaces that target intact nerve, the MSE's implantation requires transection and subsequent regeneration of the target nerve. Therefore, a key determinant of the MSE's suitability for this task is whether it can elicit sensory percepts at low current levels in the face of altered morphology and caliber distribution inherent to axon regeneration. The present study describes a combined rat sciatic nerve and behavioral model developed to answer this question. Rats learned a go/no-go detection task using auditory stimuli and then underwent surgery to implant the MSE in the sciatic nerve. After healing, they were trained with monopolar electrical stimuli with one multi-channel and eight single-channel stimulus configurations. Psychometric curves derived by the method of constant stimuli (MCS) were used to calculate 50% detection thresholds and associated psychometric slopes. Thresholds and slopes were calculated at two time points 3 weeks apart. For the multi-channel stimulus configuration, the average current required for stimulus detection was 19.37 μA (3.87 nC) per channel. Single-channel thresholds for leads located near the nerve's center were, on average, half those of leads located near the periphery (54.92 μA vs. 110.71 μA, or 10.98 nC vs. 22.14 nC). Longitudinally, 3 of 5 leads' thresholds decreased or remained stable over the 3-week span. The remaining two leads' thresholds increased by 70-74%, possibly due to scarring or device failure. This work represents an important first step in establishing the MSE's viability as a sensory feedback interface. It further lays the groundwork for future experiments that will extend this model to the study of other devices, stimulus parameters, and task paradigms.

References
1.
Davis T, Wark H, Hutchinson D, Warren D, ONeill K, Scheinblum T . Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves. J Neural Eng. 2016; 13(3):036001. DOI: 10.1088/1741-2560/13/3/036001. View

2.
Wichmann F, Hill N . The psychometric function: II. Bootstrap-based confidence intervals and sampling. Percept Psychophys. 2002; 63(8):1314-29. DOI: 10.3758/bf03194545. View

3.
Lefurge T, Goodall E, Horch K, Stensaas L, Schoenberg A . Chronically implanted intrafascicular recording electrodes. Ann Biomed Eng. 1991; 19(2):197-207. DOI: 10.1007/BF02368469. View

4.
Ceballos D, Valero-Cabre A, Valderrama E, Schuttler M, Stieglitz T, Navarro X . Morphologic and functional evaluation of peripheral nerve fibers regenerated through polyimide sieve electrodes over long-term implantation. J Biomed Mater Res. 2002; 60(4):517-28. DOI: 10.1002/jbm.10099. View

5.
Gaese B, King I, Felsheim C, Ostwald J, von der Behrens W . Discrimination of direction in fast frequency-modulated tones by rats. J Assoc Res Otolaryngol. 2006; 7(1):48-58. PMC: 2504587. DOI: 10.1007/s10162-005-0022-7. View