Vitamin E Highly Cross-linked Polyethylene Reduces Mid-term Wear in Primary Total Hip Replacement: a Meta-analysis and Systematic Review of Randomized Clinical Trials Using Radiostereometric Analysis

Overview
Journal EFORT Open Rev
Specialty Orthopedics
Date 2021 Oct 20
PMID 34667647
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Vitamin E incorporation into highly cross-linked polyethylene (HXLPE) has been introduced to improve wear resistance, and vitamin E incorporated HXLPE (VEPE) has been used in total hip arthroplasty.The aim of this meta-analysis was to investigate the wear properties of VEPE in clinical practice by synthesizing the data provided in randomized clinical trials.The effects on implant stability, functional outcomes and revision rate of VEPE were also compared with those of HXPLE or ultra-high molecular weight polyethylene (UHMWPE).Literature searches were conducted on 1 January 2020 using MEDLINE, EMBASE, Cochrane and ClinicalTrials.gov databases. Randomized controlled trials (RCTs) comparing the aforementioned parameters between VEPE and standard HXPLE/UHMWPE liners were included.Methodological quality and the bias of the included studies were analysed. Meta-analyses were performed using the Review Manager software.Nine RCTs met the eligibility criteria and were included. At early and mid-term follow-up, the vertical penetration and the total penetration of the femoral head were both significantly reduced in the VEPE group. The steady state wear rate of the VEPE group was also remarkably lower.However, at two-year follow-up, significantly increased cup migration was observed in the VEPE group. Moreover, the mid-term clinical outcomes of the VEPE group were worse, while the total revision rates between the two groups were not significantly different.The limited number of included studies may compromise our conclusion regarding clinical outcomes of the VEPE bearing surface. More RCTs with longer follow-up periods are needed to further investigate the effects of VEPE in total hip arthroplasty. Cite this article: 2021;6:759-770. DOI: 10.1302/2058-5241.6.200072.

Citing Articles

Ten-year clinical and radiological outcomes with a vitamin E-infused highly cross-linked polyethylene acetabular cup.

Afghanyar Y, Afghanyar B, Loweg L, Drees P, Gercek E, Dargel J Bone Jt Open. 2024; 5(10):825-831.

PMID: 39357881 PMC: 11446611. DOI: 10.1302/2633-1462.510.BJO-2023-0179.R1.


Head, acetabular liner composition, and rate of revision and wear in total hip arthroplasty: a Bayesian network meta-analysis.

Merfort R, Maffulli N, Hofmann U, Hildebrand F, Simeone F, Eschweiler J Sci Rep. 2023; 13(1):20327.

PMID: 37989863 PMC: 10663607. DOI: 10.1038/s41598-023-47670-z.


An isoelastic monoblock cup versus a modular metal-back cup: a matched-pair analysis of clinical and radiological results using Einzel-Bild-Röntgen-Analyse software.

Afghanyar Y, Moller J, Wunderlich F, Dargel J, Rehbein P, Gercek E Arch Orthop Trauma Surg. 2023; 144(1):493-500.

PMID: 37740060 PMC: 10774207. DOI: 10.1007/s00402-023-05058-8.

References
1.
Dumbleton J, DAntonio J, Manley M, Capello W, Wang A . The basis for a second-generation highly cross-linked UHMWPE. Clin Orthop Relat Res. 2006; 453:265-71. DOI: 10.1097/01.blo.0000238856.61862.7d. View

2.
Luo D, Wan X, Liu J, Tong T . Optimally estimating the sample mean from the sample size, median, mid-range, and/or mid-quartile range. Stat Methods Med Res. 2016; 27(6):1785-1805. DOI: 10.1177/0962280216669183. View

3.
Langlois J, Atlan F, Scemama C, Courpied J, Hamadouche M . A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components. Bone Joint J. 2015; 97-B(11):1458-62. DOI: 10.1302/0301-620X.97B11.36219. View

4.
Wan X, Wang W, Liu J, Tong T . Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range. BMC Med Res Methodol. 2014; 14:135. PMC: 4383202. DOI: 10.1186/1471-2288-14-135. View

5.
Schulte K, Callaghan J, Kelley S, Johnston R . The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J Bone Joint Surg Am. 1993; 75(7):961-75. DOI: 10.2106/00004623-199307000-00002. View