» Articles » PMID: 34664845

A Randomized Crossover Pilot Study Comparing the Efficacy of an Auto-demand Oxygen Delivery System with That of a Conventional Demand Oxygen Delivery System in Patients with Chronic Respiratory Failure

Overview
Specialty General Medicine
Date 2021 Oct 19
PMID 34664845
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: : When using portable oxygen, a demand oxygen delivery system (DODS), which senses the beginning of inhalation and delivers a bolus of oxygen, is often used. However, conventional DODS may not supply sufficient oxygen when reduced tidal flow fails to trigger the flow sensor. Recently, "auto-DODS," which detects the negative pressure of inhalation and switches among 3 trigger sensitivity levels (standard, high, and extra high), has been developed to improve the efficacy of oxygenation. An auto-DODS can also supply pulsed-flow oxygen when it detects apnea, whereas a conventional DODS has only standard sensitivity. This randomized, open-label, crossover pilot study compared the performance of an auto-DODS with that of a conventional DODS.

Methods: : We recruited patients with chronic obstructive pulmonary disease (COPD) or interstitial pneumonia receiving long-term oxygen therapy. Interventions were performed on 2 different days for each participant. On each day, an auto-DODS or a conventional DODS were tested at rest for 30 minutes and during the 6-minute walk test. The primary outcome was mean oxygen saturation (SpO2). Secondary outcomes were the ratios of time for each sensitivity level and pulsed-flow oxygen when using the auto-DODS, total time desaturated below SpO2 90%, percentage of time desaturated below SpO2 90%, minimum SpO2, mean and maximum pulse rate, six-minute walk distance, recovery time after 6-minute walk test, modified Borg scale, comfort, and discomfort index.

Results: : When using the auto-DODS at rest, a high or extra high sensitivity level was observed in addition to standard sensitivity in 6 of 8 participants. During the 6-minute walk test, only standard sensitivity was observed in 6 participants. Mean SpO2 differences between the auto-DODS and conventional DODS at rest and during the 6-minute walk test were -0.6 [-4.5, 3.4] and 0.0 [-2.5, 2.5] ([95% confidence interval]), respectively, neither of which were significant (P = .73 and P = .99). There were no significant differences in secondary outcomes. There were no adverse events when using the auto-DODS.

Conclusions: : This study showed that the auto-DODS did not show superiority in oxygenation either at rest or during exercise compared to a conventional DODS. The auto-DODS was shown to supply oxygen safely and detect inhalations with various trigger sensitivities.

Citing Articles

Clinical analysis of 45 cases of chronic respiratory failure treated by noninvasive ventilator combined with bronchodilator and anti-infective drugs.

Huang H, Xu Y, Li Q Eur J Med Res. 2025; 30(1):101.

PMID: 39953618 PMC: 11827159. DOI: 10.1186/s40001-025-02341-9.


Randomized crossover trial of a demand oxygen delivery system in nocturnal hypoxemia.

Yatani A, Nagano T, Murakami S, Otoshi T, Hazama D, Katsurada N Sci Rep. 2024; 14(1):20505.

PMID: 39227657 PMC: 11372129. DOI: 10.1038/s41598-024-71320-7.


Comparison of the effects of different mechanical ventilation modes on the incidence of ventilation-associated pneumonia: a case study of patients undergoing thoracic surgery.

Liu X, Wang L Am J Transl Res. 2023; 14(12):8668-8675.

PMID: 36628217 PMC: 9827302.

References
1.
. Continuous or nocturnal oxygen therapy in hypoxemic chronic obstructive lung disease: a clinical trial. Nocturnal Oxygen Therapy Trial Group. Ann Intern Med. 1980; 93(3):391-8. DOI: 10.7326/0003-4819-93-3-391. View

2.
Yanez A, Prat J, Alvarez-Sala J, Calle M, Diaz Lobato S, Garcia Gonzalez J . Oxygenation With a Single Portable Pulse-Dose Oxygen-Conserving Device and Combined Stationary and Portable Oxygen Delivery Devices in Subjects With COPD. Respir Care. 2014; 60(3):382-7. DOI: 10.4187/respcare.03470. View

3.
Lee G, Lee S, Oh Y, Lee J, Lee S, Shin C . A pilot study comparing 2 oxygen delivery methods for patients' comfort and administration of oxygen. Respir Care. 2013; 59(8):1191-8. DOI: 10.4187/respcare.02937. View

4.
Tiep B, Carter R, Nicotra B, Berry J, Phillips R, Otsap B . Demand oxygen delivery during exercise. Chest. 1987; 91(1):15-20. DOI: 10.1378/chest.91.1.15. View

5.
Bower J, Brook C, Zimmer K, Davis D . Performance of a demand oxygen saver system during rest, exercise, and sleep in hypoxemic patients. Chest. 1988; 94(1):77-80. DOI: 10.1378/chest.94.1.77. View