» Articles » PMID: 34602736

Electrode Scalp Impedance Differences Between Electroencephalography Machines in Healthy Dogs

Overview
Journal Can J Vet Res
Date 2021 Oct 4
PMID 34602736
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Scalp electrode impedance measurements recorded by wired and wireless electroencephalography (EEG) machines in 7 healthy dogs were compared. Eight recordings resulted in 80 impedance readings from subdermal wire electrodes (locations F7/F8, F3/F4, T3/T4, C3/C4, Fz, and Cz). Impedance values were measured first from the wired and then the wireless EEG machine. Wireless impedance measurements were higher than the wired EEG machine in 79/80 readings ( ≤ 0.05), being on average 2.83 kΩ [ ≤ 0.05, 95% confidence interval (CI): 2.51 to 3.14, SD = 1.42] higher. Impedances from the wired machine ranged between < 0.5 and 9 kΩ (mean = 3.09, median = 2.00, SD = 2.15), whereas impedances from the wireless machine ranged between 2.69 and 6.07 kΩ (mean = 5.92, median = 5.05, SD = 2.59). Despite these differences in impedance measurements, both machines measured similar impedance patterns. The wireless EEG machine's impedance measurements, therefore, should be acceptable for veterinary clinical settings.

Citing Articles

Non-invasive canine electroencephalography (EEG): a systematic review.

Kulgod A, van der Linden D, Franca L, Jackson M, Zamansky A BMC Vet Res. 2025; 21(1):73.

PMID: 39966923 PMC: 11834203. DOI: 10.1186/s12917-025-04523-3.


Survey of electroencephalography usage and techniques for dogs.

Luca J, McCarthy S, Parmentier T, Hazenfratz M, Zur Linden A, Gaitero L Front Vet Sci. 2023; 10:1198134.

PMID: 37520003 PMC: 10374286. DOI: 10.3389/fvets.2023.1198134.


Transcutaneous Cervical Vagus Nerve Stimulation Induces Changes in the Electroencephalogram and Heart Rate Variability of Healthy Dogs, a Pilot Study.

Castillo G, Gaitero L, Fonfara S, Czura C, Monteith G, James F Front Vet Sci. 2022; 9:878962.

PMID: 35769324 PMC: 9234651. DOI: 10.3389/fvets.2022.878962.

References
1.
Kappenman E, Luck S . The effects of electrode impedance on data quality and statistical significance in ERP recordings. Psychophysiology. 2010; 47(5):888-904. PMC: 2902592. DOI: 10.1111/j.1469-8986.2010.01009.x. View

2.
Chandler K . Canine epilepsy: what can we learn from human seizure disorders?. Vet J. 2005; 172(2):207-17. DOI: 10.1016/j.tvjl.2005.07.001. View

3.
Packer R, Berendt M, Bhatti S, Charalambous M, Cizinauskas S, De Risio L . Inter-observer agreement of canine and feline paroxysmal event semiology and classification by veterinary neurology specialists and non-specialists. BMC Vet Res. 2015; 11:39. PMC: 4337258. DOI: 10.1186/s12917-015-0356-2. View

4.
James F, Cortez M, Monteith G, Jokinen T, Sanders S, Wielaender F . Diagnostic Utility of Wireless Video-Electroencephalography in Unsedated Dogs. J Vet Intern Med. 2017; 31(5):1469-1476. PMC: 5598905. DOI: 10.1111/jvim.14789. View

5.
De Risio L, Bhatti S, Munana K, Penderis J, Stein V, Tipold A . International veterinary epilepsy task force consensus proposal: diagnostic approach to epilepsy in dogs. BMC Vet Res. 2015; 11:148. PMC: 4552251. DOI: 10.1186/s12917-015-0462-1. View