Development of an Electronic Portal Imaging Device Dosimetry Method

Overview
Specialty Radiology
Date 2021 Sep 28
PMID 34573994
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Support arm backscatter and off-axis effects of an electronic portal imaging device (EPID) are challenging for radiotherapy quality assurance. Aiming at the issue, we proposed a simple yet effective method with correction matrices to rectify backscatter and off-axis responses for EPID images. First, we measured the square fields with ionization chamber array (ICA) and EPID simultaneously. Second, we calculated the dose-to-pixel value ratio and used it as the correction matrix of the corresponding field. Third, the correction value of the large field was replaced with that of the same point in the small field to generate a correction matrix suitable for different EPID images. Finally, we rectified the EPID image with the correction matrix, and then the processed EPID images were converted into the absolute dose. The calculated dose was compared with the measured dose via ICA. The gamma pass rates of 3%/3 mm and 2%/2 mm (5% threshold) were 99.6% ± 0.94% and 95.48% ± 1.03%, and the average gamma values were 0.28 ± 0.04 and 0.42 ± 0.05, respectively. Experimental results verified our method accurately corrected EPID images and converted pixel values into absolute dose values such that EPID was an efficient radiotherapy dosimetry tool.

Citing Articles

A Novel Approach for Position Verification and Dose Calculation through Local MVCT Reconstruction.

Zhang J, Chen Z, Lei Y, Wen J Diagnostics (Basel). 2024; 14(5).

PMID: 38472954 PMC: 10931282. DOI: 10.3390/diagnostics14050482.


Using eclipse scripting to fully automate in-vivo image analysis to improve treatment quality and safety.

Chalise A, Bojechko C J Appl Clin Med Phys. 2022; 23(6):e13585.

PMID: 35315570 PMC: 9194972. DOI: 10.1002/acm2.13585.

References
1.
Camilleri J, Mazurier J, Franck D, Dudouet P, Latorzeff I, Franceries X . 2D EPID dose calibration for pretreatment quality control of conformal and IMRT fields: A simple and fast convolution approach. Phys Med. 2015; 32(1):133-40. DOI: 10.1016/j.ejmp.2015.10.094. View

2.
Martinez Ortega J, Gomez Gonzalez N, Castro Tejero P, Pinto Monedero M, Tolani N, Nunez Martin L . A portal dosimetry dose prediction method based on collapsed cone algorithm using the clinical beam model. Med Phys. 2017; 44(1):333-341. DOI: 10.1002/mp.12018. View

3.
Greer P . Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry. Med Phys. 2006; 32(12):3558-68. DOI: 10.1118/1.2128498. View

4.
Van Esch A, Huyskens D, Hirschi L, Baltes C . Optimized Varian aSi portal dosimetry: development of datasets for collective use. J Appl Clin Med Phys. 2013; 14(6):4286. PMC: 5714635. DOI: 10.1120/jacmp.v14i6.4286. View

5.
Rowshanfarzad P, Sabet M, OConnor D, Greer P . Improvement of Varian a-Si EPID dosimetry measurements using a lead-shielded support-arm. Med Dosim. 2011; 37(2):145-51. DOI: 10.1016/j.meddos.2011.06.003. View