» Articles » PMID: 34572397

Correlation of Pulse Wave Transit Time with Pulmonary Artery Pressure in a Porcine Model of Pulmonary Hypertension

Abstract

For the non-invasive assessment of pulmonary artery pressure (PAP), surrogates like pulse wave transit time (PWTT) have been proposed. The aim of this study was to invasively validate for which kind of PAP (systolic, mean, or diastolic) PWTT is the best surrogate parameter. To assess both PWTT and PAP in six healthy pigs, two pulmonary artery Mikro-Tip™ catheters were inserted into the pulmonary vasculature at a fixed distance: one in the pulmonary artery trunk, and a second one in a distal segment of the pulmonary artery. PAP was raised using the thromboxane A2 analogue U46619 (TXA) and by hypoxic vasoconstriction. There was a negative linear correlation between PWTT and systolic PAP ( = 0.742), mean PAP ( = 0.712) and diastolic PAP ( = 0.609) under TXA. During hypoxic vasoconstriction, the correlation coefficients for systolic, mean, and diastolic PAP were consistently higher than for TXA-induced pulmonary hypertension ( = 0.809, 0.778 and 0.734, respectively). Estimation of sPAP, mPAP, and dPAP using PWTT is feasible, nevertheless slightly better correlation coefficients were detected for sPAP compared to dPAP. In this study we establish the physiological basis for future methods to obtain PAP by non-invasively measured PWTT.

Citing Articles

Assessment of Long-Term Sequelae of Pulmonary Dysfunction Associated with COVID-19 Using Pulmonary Pulse Transit Time.

Duran M, Uygun T, Kurtipek E J Cardiovasc Echogr. 2023; 32(4):200-204.

PMID: 36994124 PMC: 10041403. DOI: 10.4103/jcecho.jcecho_31_22.


Ventilation Induces Changes in Pulse Wave Transit Time in the Pulmonary Artery.

Mueller-Graf F, Frenkel P, Albus C, Henkel M, Reuter S, Vollmar B Biomedicines. 2023; 11(1).

PMID: 36672690 PMC: 9855784. DOI: 10.3390/biomedicines11010182.

References
1.
Sola J, Adler A, Santos A, Tusman G, Suarez Sipmann F, Bohm S . Non-invasive monitoring of central blood pressure by electrical impedance tomography: first experimental evidence. Med Biol Eng Comput. 2011; 49(4):409-15. DOI: 10.1007/s11517-011-0753-z. View

2.
Proenca M, Braun F, Lemay M, Sola J, Adler A, Riedel T . Non-invasive pulmonary artery pressure estimation by electrical impedance tomography in a controlled hypoxemia study in healthy subjects. Sci Rep. 2020; 10(1):21462. PMC: 7722929. DOI: 10.1038/s41598-020-78535-4. View

3.
MILNOR W, Conti C, Lewis K, ORourke M . Pulmonary arterial pulse wave velocity and impedance in man. Circ Res. 1969; 25(6):637-49. DOI: 10.1161/01.res.25.6.637. View

4.
Gesche H, Grosskurth D, Kuchler G, Patzak A . Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method. Eur J Appl Physiol. 2011; 112(1):309-15. DOI: 10.1007/s00421-011-1983-3. View

5.
Galie N, Humbert M, Vachiery J, Gibbs S, Lang I, Torbicki A . 2015 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension: The Joint Task Force for the Diagnosis and Treatment of Pulmonary Hypertension of the European Society of Cardiology (ESC) and the European Respiratory Society (ERS):.... Eur Heart J. 2015; 37(1):67-119. DOI: 10.1093/eurheartj/ehv317. View