» Articles » PMID: 34567683

Capacitive Micromachined Ultrasound Transducers for Intravascular Ultrasound Imaging

Overview
Date 2021 Sep 27
PMID 34567683
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Intravascular ultrasound (IVUS) is a burgeoning imaging technology that provides vital information for the diagnosis of coronary arterial diseases. A significant constituent that enables the IVUS system to attain high-resolution images is the ultrasound transducer, which acts as both a transmitter that sends acoustic waves and a detector that receives the returning signals. Being the most mature form of ultrasound transducer available in the market, piezoelectric transducers have dominated the field of biomedical imaging. However, there are some drawbacks associated with using the traditional piezoelectric ultrasound transducers such as difficulties in the fabrication of high-density arrays, which would aid in the acceleration of the imaging speed and alleviate motion artifact. The advent of microelectromechanical system (MEMS) technology has brought about the development of micromachined ultrasound transducers that would help to address this issue. Apart from the advantage of being able to be fabricated into arrays with lesser complications, the image quality of IVUS can be further enhanced with the easy integration of micromachined ultrasound transducers with complementary metal-oxide-semiconductor (CMOS). This would aid in the mitigation of parasitic capacitance, thereby improving the signal-to-noise. Currently, there are two commonly investigated micromachined ultrasound transducers, piezoelectric micromachined ultrasound transducers (PMUTs) and capacitive micromachined ultrasound transducers (CMUTs). Currently, PMUTs face a significant challenge where the fabricated PMUTs do not function as per their design. Thus, CMUTs with different array configurations have been developed for IVUS. In this paper, the different ultrasound transducers, including conventional-piezoelectric transducers, PMUTs and CMUTs, are reviewed, and a summary of the recent progress of CMUTs for IVUS is presented.

Citing Articles

Mid-Infrared Photonic Sensors: Exploring Fundamentals, Advanced Materials, and Cutting-Edge Applications.

Butt M, Juchniewicz M, Slowikowski M, Kozlowski L, Piramidowicz R Sensors (Basel). 2025; 25(4).

PMID: 40006331 PMC: 11859392. DOI: 10.3390/s25041102.


Flexible micromachined ultrasound transducers (MUTs) for biomedical applications.

Joshi S, Sadeghpour S, Kuznetsova N, Wang C, Kraft M Microsyst Nanoeng. 2025; 11(1):9.

PMID: 39814707 PMC: 11736036. DOI: 10.1038/s41378-024-00783-5.


Biomarker detection based on nanoparticle-induced ultrasonic Rayleigh scattering.

Zhang W, Zhao C, Jia H, Liu T, Yang J, Wu P Microsyst Nanoeng. 2024; 10(1):182.

PMID: 39632870 PMC: 11618333. DOI: 10.1038/s41378-024-00808-z.


Coil-Only High-Frequency Lamb Wave Generation in Nickel Sheets.

Song Y, Kang Y, Wang K, Guo Y, Tu J, Feng B Sensors (Basel). 2024; 24(22).

PMID: 39598919 PMC: 11598791. DOI: 10.3390/s24227141.


A low-voltage-driven MEMS ultrasonic phased-array transducer for fast 3D volumetric imaging.

Zhang Y, Jin T, Deng Y, Zhao Z, Wang R, He Q Microsyst Nanoeng. 2024; 10(1):128.

PMID: 39261463 PMC: 11391059. DOI: 10.1038/s41378-024-00755-9.


References
1.
Goh A, Kohn J, Rootman D, Lin J, Goldberg R . Hyaluronic acid gel distribution pattern in periocular area with high-resolution ultrasound imaging. Aesthet Surg J. 2014; 34(4):510-5. DOI: 10.1177/1090820X14528206. View

2.
Lv J, Li S, Zhang J, Duan F, Wu Z, Chen R . photoacoustic imaging dynamically monitors the structural and functional changes of ischemic stroke at a very early stage. Theranostics. 2020; 10(2):816-828. PMC: 6929999. DOI: 10.7150/thno.38554. View

3.
Yeh D, Oralkan O, Wygant I, ODonnell M, Khuri-Yakub B . 3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications. IEEE Trans Ultrason Ferroelectr Freq Control. 2006; 53(6):1202-11. DOI: 10.1109/tuffc.2006.1642519. View

4.
Nie L, Guo Z, Wang L . Photoacoustic tomography of monkey brain using virtual point ultrasonic transducers. J Biomed Opt. 2011; 16(7):076005. PMC: 3144974. DOI: 10.1117/1.3595842. View

5.
Chin C, Maehara A, Fall K, Mintz G, Ali Z . Imaging Comparisons of Coregistered Native and Stented Coronary Segments by High-Definition 60-MHz Intravascular Ultrasound and Optical Coherence Tomography. JACC Cardiovasc Interv. 2016; 9(12):1305-1306. DOI: 10.1016/j.jcin.2016.04.011. View