» Articles » PMID: 34558141

Differentiation of Diffuse Infiltration Pattern in Multiple Myeloma From Hyperplastic Hematopoietic Bone Marrow: Qualitative and Quantitative Analysis Using Whole-Body MRI

Overview
Date 2021 Sep 24
PMID 34558141
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The visual assessment used for diffuse infiltration of multiple myeloma (MM) is inadequate. It can be difficult to differentiate MM from hyperplastic hematopoietic bone marrow (HHBM) because the MRI signal characteristics overlap.

Purpose: To analyze the bone marrow diffuse signal changes on whole-body MRI caused by MM and HHBM.

Study Type: Retrospective.

Subjects: Thirty Four patients with MM (21 men and 13 women), 22 patients with HHBM (9 men and 13 women), and 15 healthy controls (9 men and 6 women).

Field Strength/sequence: A 3.0 T MRI; diffusion-weighted whole-body imaging with background body signal suppression (DWIBS), modified Dixon T1 fast field echo, and T2 STIR.

Assessment: Three radiologists analyzed the whole-body MRI alone and in combination with apparent diffusion coefficient (ADC) and fat fraction (FF) with qualitative and quantitative analysis. Normalized T1 and T2 signal intensities (nT1 and nT2) and signal-to-noise ratio (SNR) were obtained.

Statistical Tests: Kruskal-Wallis and chi-square tests.

Results: The MM group had significantly higher ADC and significantly lower FF than HHBM and control groups. There was no significant difference in nT1, nT2 or SNR between MM and HHBM (P = 0.932, P = 0.097, and P = 0.110, respectively). Receiver operating characteristic (ROC) analysis using ADC and FF cut-off values of 0.47 × 10  mm /sec and 20.63%, respectively. The AUC was 0.866 for ADC and 0.886 for FF. The quantitative analysis yielded better specificity (observer 1: 81.8% vs. 27.3%; observer 2: 68.2% vs. 22.7%; and observer 3: 72.7% vs. 18.2%) and a higher diagnostic accuracy (observer 1: 82.1% vs. 51.8%; observer 2: 80.4% vs. 50.0%; observer 3: 76.8% vs. 44.6%) than the qualitative analysis.

Data Conclusion: Whole-body MRI combined with DWIBS and mDIXON could be used to differentiate between MM and HHBM. Combining the quantitative ADC and FF with the whole-body MRI improved the specificity and accuracy in differentiating these conditions.

Evidence Level: 3 TECHNICAL EFFICACY: Stage 2.

Citing Articles

Predicting cytogenetic risk in multiple myeloma using conventional whole-body MRI, spinal dynamic contrast-enhanced MRI, and spinal diffusion-weighted imaging.

Den Berghe T, Verberckmoes B, Kint N, Wallaert S, De Vos N, Algoet C Insights Imaging. 2024; 15(1):106.

PMID: 38597979 PMC: 11006637. DOI: 10.1186/s13244-024-01672-1.


Normal bone marrow signal characteristics in whole-body diffusion-weighted images of amateur marathon runners.

Cao H, Cui F, Yu H, Cui J, Ma F, Duan L Quant Imaging Med Surg. 2024; 14(3):2321-2333.

PMID: 38545071 PMC: 10963844. DOI: 10.21037/qims-23-1006.


Correlation between whole skeleton dual energy CT calcium-subtracted attenuation and bone marrow infiltration in multiple myeloma.

Gu R, Amlani A, Haberland U, Hodson D, Streetly M, Antonelli M Eur J Radiol. 2022; 149:110223.

PMID: 35240412 PMC: 9026281. DOI: 10.1016/j.ejrad.2022.110223.


Proton Density Fat Fraction Spine MRI for Differentiation of Erosive Vertebral Endplate Degeneration and Infectious Spondylitis.

Schmeel F, Lakghomi A, Lehnen N, Haase R, Banat M, Wach J Diagnostics (Basel). 2022; 12(1).

PMID: 35054245 PMC: 8774963. DOI: 10.3390/diagnostics12010078.