Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks

Overview
Date 2021 Sep 23
PMID 34552968
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Night-time heart rate (HR) is expected to reflect more accurately the cardiac autonomic function of modulating cardiovascular activity. Few studies have been conducted on the predictive values of night-time HR in relation to cardioverter-defibrillator therapies. To explore the associations of night-time HR with the ventricular tachyarrhythmias (VTAs), appropriate and inappropriate implantable cardioverter-defibrillator (ICD) shocks. Patients from the SUMMIT registry receiving ICD or cardiac resynchronization therapy with defibrillator (CRT-D) implantation were retrospectively analyzed using archived home monitoring data. Night-time HR was recorded from 2:00 am to 6:00 am during the first 30 to 60 days after implantation. VTA events and ICD shocks were identified using the intracardiac electrograms by two independent physicians. Restricted cubic splines and smooth curve fitting were conducted to address the non-linear associations between night-time HR and adjusted hazards for clinical outcomes. Over a mean follow-up duration of 55.8 ± 22.7 months, 187 deaths were observed among 730 patients. VTAs, appropriate and inappropriate ICD shocks were observed in 422 (57.8%), 293 (40.1%), and 72 (10.0%) patients, respectively. Apparent U-shaped non-linear associations of night-time HR with VTAs (P for non-linearity = 0.007), appropriate ICD shocks (P for non-linearity = 0.003) and inappropriate ICD shocks (P for non-linearity = 0.014) were detected. When night-time HR was beyond 60 bpm, every 1 bpm increase in night-time HR could result in 3.2, 3.3, and 4.9% higher risks of VTAs and appropriate and inappropriate ICD shocks, respectively; when night-time HR was lower than 60 bpm, every 1 bpm increase in night-time HR could result in 6.0 and 10.7% lower risks of appropriate and inappropriate ICD shocks. Compared to night-time HR of ≤ 50 or ≥70 bpm, night-time HR of 50-70 bpm was associated with 24.9, 30.2, 63.5, and 31.5% reduced incidences of VTA events, appropriate ICD shocks, inappropriate ICD shocks, and all-cause mortality, respectively. Apparent non-linear associations of night-time HR with VTAs and ICD shocks were detected. An increasing incidence of VTAs and ICD shocks was observed at both low and high levels of night-time HR. Night-time HR of 50-70 bpm might be the optimal therapeutics target for the management of ICD/CRT-D recipients.

Citing Articles

Contemporary Management and Prognostic Factors of Arrhythmia Recurrence in Patients with High-Energy Discharge of Cardiac Implantable Electronic Devices.

Kampka Z, Drabczyk M, Pajak M, Drapacz O, Orszulak M, Cichon M Medicina (Kaunas). 2024; 60(10).

PMID: 39459449 PMC: 11509349. DOI: 10.3390/medicina60101662.

References
1.
Kleemann T, Strauss M, Kouraki K, Zahn R . Clinical course and prognostic relevance of antitachycardia pacing-terminated ventricular tachyarrhythmias in implantable cardioverter-defibrillator patients. Europace. 2015; 17(7):1068-75. DOI: 10.1093/europace/euv007. View

2.
Ruwald A, Schuger C, Moss A, Kutyifa V, Olshansky B, Greenberg H . Mortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT). Circ Arrhythm Electrophysiol. 2014; 7(5):785-92. DOI: 10.1161/CIRCEP.114.001623. View

3.
Kannel W, Kannel C, Paffenbarger Jr R, Cupples L . Heart rate and cardiovascular mortality: the Framingham Study. Am Heart J. 1987; 113(6):1489-94. DOI: 10.1016/0002-8703(87)90666-1. View

4.
Beinart R, Kutyifa V, McNitt S, Huang D, Aktas M, Rosero S . Relation between resting heart rate and the risk of ventricular tachyarrhythmias in MADIT-RIT. Europace. 2020; 22(2):281-287. DOI: 10.1093/europace/euz353. View

5.
Li S, Sartipy U, Lund L, Dahlstrom U, Adiels M, Petzold M . Prognostic Significance of Resting Heart Rate and Use of β-Blockers in Atrial Fibrillation and Sinus Rhythm in Patients With Heart Failure and Reduced Ejection Fraction: Findings From the Swedish Heart Failure Registry. Circ Heart Fail. 2015; 8(5):871-9. DOI: 10.1161/CIRCHEARTFAILURE.115.002285. View