A Blood-mimicking Fluid with Cholesterol As Scatter Particles for Wall-less Carotid Artery Phantom Applications

Overview
Journal J Ultrason
Date 2021 Sep 20
PMID 34540276
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

At present, there are few scatter particles used in preparing blood-mimicking fluids, such as nylon, sephadex, polystyrene microsphere, and poly(4-methystyrene). In this study, we present cholesterol as a new scatter particle for blood-mimicking fluid preparation. The procedure for the preparation of the proposed blood-mimicking fluid involved the use of propylene glycol, D(+)-Glucose and distilled water to form a ternary mixture fluid, with cholesterol used as scatter particles. Polyethylene glycol was first used as part of the mixture fluid but the acoustic and physical properties were not suitable, leading to its replacement with D(+)-Glucose, which is soluble in water and has a higher density. A common carotid artery wall-less phantom was also produced to assess the flow properties. The prepared blood-mimicking fluid with new scatter particles has a density of 1.067 g/cm, viscosity of 4.1 mPa.s, speed of sound 1600 m/s, and attenuation of 0.192 dB/cm at 5 MHz frequency. Peak systolic velocity, end diastolic velocity and mean velocity measurements were gotten to be 40.2 ± 2.4 cm/s, 9.9 ± 1.4 cm/s, and 24.0 ± 1.8 cm/s, respectively. Based on the results obtained, the blood-mimicking fluid was found suitable for ultrasound applications in carotid artery wall-less phantoms because of its good acoustic and physical properties.

Citing Articles

A Review of Blood-mimicking Fluid Properties Using Doppler Ultrasound Applications.

Oglat A J Med Ultrasound. 2023; 30(4):251-256.

PMID: 36844776 PMC: 9944827. DOI: 10.4103/jmu.jmu_60_22.


Performance Evaluation of an Ultrasonic Imaging System Using Tissue-Mimicking Phantoms for Quality Assurance.

Oglat A Biomimetics (Basel). 2022; 7(3).

PMID: 36134934 PMC: 9496229. DOI: 10.3390/biomimetics7030130.


Abnormal expression of long non-coding RNA rhabdomyosarcoma 2-associated transcript (RMST) participates in the pathological mechanism of atherosclerosis by regulating miR-224-3p.

Zhang T, Feng C, Zhang X, Sun B, Bian Y Bioengineered. 2022; 13(2):2648-2657.

PMID: 35067166 PMC: 8974166. DOI: 10.1080/21655979.2021.2023995.

References
1.
Rickey D, Picot P, Christopher D, Fenster A . A wall-less vessel phantom for Doppler ultrasound studies. Ultrasound Med Biol. 1995; 21(9):1163-76. DOI: 10.1016/0301-5629(95)00044-5. View

2.
Samavat H, Evans J . An ideal blood mimicking fluid for doppler ultrasound phantoms. J Med Phys. 2011; 31(4):275-8. PMC: 3004103. DOI: 10.4103/0971-6203.29198. View

3.
Yousif M, Holdsworth D, Poepping T . Deriving a blood-mimicking fluid for particle image velocimetry in Sylgard-184 vascular models. Annu Int Conf IEEE Eng Med Biol Soc. 2009; 2009:1412-5. DOI: 10.1109/IEMBS.2009.5334175. View

4.
Boote E, Zagzebski J . Performance tests of Doppler ultrasound equipment with a tissue and blood-mimicking phantom. J Ultrasound Med. 1988; 7(3):137-47. DOI: 10.7863/jum.1988.7.3.137. View

5.
Virani S, Catellier D, Pompeii L, Nambi V, Hoogeveen R, Wasserman B . Relation of cholesterol and lipoprotein parameters with carotid artery plaque characteristics: the Atherosclerosis Risk in Communities (ARIC) carotid MRI study. Atherosclerosis. 2011; 219(2):596-602. PMC: 3226845. DOI: 10.1016/j.atherosclerosis.2011.08.001. View