» Articles » PMID: 34459948

Correlation of Near-Infrared Spectroscopy Oximetry and Corresponding Venous Oxygen Saturations in Children with Congenital Heart Disease

Overview
Journal Pediatr Cardiol
Date 2021 Aug 30
PMID 34459948
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Invasive and non-invasive monitoring allow for early detection of hemodynamic compromise, facilitating timely intervention and avoidance of further decline. While venous oximetry is useful for assessing the adequacy of systemic oxygen delivery (DO), it is most often intermittent, invasive, and costly. Near-infrared spectroscopy (NIRS) oximetry allows for the non-invasive estimation of the adequacy of DO. We assessed the correlation between cerebral NIRS oximetry and superior vena cava (SVC) and jugular venous (JV) oxygen saturations and between renal NIRS oximetry and inferior vena cava (IVC) oxygen saturations. Systematic review of the literature was conducted to identify studies with data regarding near-infrared spectroscopy and venous saturation. The PubMed, EMBASE, Medline, and Cochrane databases were queried using the following terms in isolation and various combinations: "congenital heart disease," "near infrared spectroscopy," "venous saturation," and "pediatric." Pediatric studies in which simultaneous NIRS oximetry and corresponding venous oxygen saturations were simultaneously collected after cardiac surgery or catheterization were identified. Data were pooled from these studies to analyze the correlation between NIRS oximetry and the corresponding venous oxygen saturations. A total of 16 studies with 613 patients were included in the final analyses. Data were present to compare cerebral and renal NIRS oximetry with corresponding venous oxygen saturation. Cerebral NIRS and SVC and JV oxygen saturations and renal NIRS and IVC oxygen saturations demonstrated strong degrees of correlation (r-value 0.70 for each). However, cerebral NIRS and IVC oxygen saturation had a week degree of correlation (r-value of 0.38). Pooled analyses demonstrate that cerebral NIRS oximetry correlates strongly with SVC or JV oxygen saturation while renal NIRS oximetry correlates strongly with IVC oxygen saturations. A weak correlation was noted between cerebral NIRS oximetry and IVC oxygen saturations.

Citing Articles

Veno-Arterial Partial Pressure of Carbon Dioxide Difference as a Metric of Systemic Oxygen Delivery: Insights from a Correlative Meta-Analysis.

Loomba R, Farias J, Savorgnan F, Acosta S, Flores S, Villarreal E J Pediatr Intensive Care. 2024; 13(4):372-378.

PMID: 39629341 PMC: 11584265. DOI: 10.1055/s-0042-1743501.


Neuromonitoring practices for neonates with congenital heart disease: a scoping review.

Pardo A, Carrasco M, Wintermark P, Nunes D, Chock V, Sen S Pediatr Res. 2024; .

PMID: 39183308 DOI: 10.1038/s41390-024-03484-x.


Cerebral blood flow dynamics during cardiac surgery in infants.

Leth-Olsen M, Dohlen G, Torp H, Nyrnes S Pediatr Res. 2024; .

PMID: 38570558 DOI: 10.1038/s41390-024-03161-z.


Noninvasive tracking of mixed venous oxygen saturation via near-infrared spectroscopy cerebral oximetry: a retrospective observational study.

Oh C, Baek S, Lee S, Shim M, Han S, Kim Y Sci Rep. 2023; 13(1):21704.

PMID: 38066206 PMC: 10709586. DOI: 10.1038/s41598-023-49078-1.


The Inadequate Oxygen Delivery Index and Its Correlation with Venous Saturation in the Pediatric Cardiac Intensive Care Unit.

Loomba R, Villarreal E, Flores S, Farias J, Constas A Pediatr Cardiol. 2023; 46(1):39-45.

PMID: 37743384 DOI: 10.1007/s00246-023-03302-x.


References
1.
Bronicki R . Venous oximetry and the assessment of oxygen transport balance. Pediatr Crit Care Med. 2011; 12(4 Suppl):S21-6. DOI: 10.1097/PCC.0b013e3182211667. View

2.
Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B . Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2002; 345(19):1368-77. DOI: 10.1056/NEJMoa010307. View

3.
Ghanayem N, Hoffman G . Near Infrared Spectroscopy as a Hemodynamic Monitor in Critical Illness. Pediatr Crit Care Med. 2016; 17(8 Suppl 1):S201-6. DOI: 10.1097/PCC.0000000000000780. View

4.
Tsang R, Checchia P, Bronicki R . Hemodynamic Monitoring in the Acute Management of Pediatric Heart Failure. Curr Cardiol Rev. 2015; 12(2):112-6. PMC: 4861939. DOI: 10.2174/1573403x12666151119165007. View

5.
Rivers E, Ander D, Powell D . Central venous oxygen saturation monitoring in the critically ill patient. Curr Opin Crit Care. 2001; 7(3):204-11. DOI: 10.1097/00075198-200106000-00011. View