» Articles » PMID: 34451070

The Effect of Sleeve Pattern and Fit on E-Textile Electromyography (EMG) Electrode Performance in Smart Clothing Design

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2021 Aug 28
PMID 34451070
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

When e-textile EMG electrodes are integrated into clothing, the fit of the clothing on the body, and therefore its pattern and cut become important factors affecting the EMG signal quality in relation to the seamless contact between the skin and the e-textile electrode. The research so far on these effects was conducted on commercially available clothing or in tubular sleeve forms for arms. There is no study that investigated different clothing pattern and fit conditions and their effect on e-textile EMG electrode performance. This study investigates the effect of clothing pattern and fit in EMG applications using e-textile electrodes integrated onto the sleeves of custom drafted t-shirts in set-in and raglan sleeve pattern variations. E-textile electrode resistance, signal-to-noise ratio (SNRdB), power spectral density and electrode-skin impedance are measured and evaluated in set-in sleeve and raglan sleeve conditions with participants during a standardized arm movement protocol in comparison to the conventional hydrogel Ag/AgCl electrodes. The raglan sleeve pattern, widely used in athletic wear to provide extra ease for the movement of the shoulder joint, showed superior performance and therefore indicated the pattern and cut of a garment could have significant effect on EMG signal quality in designing smart clothing.

Citing Articles

Measuring Surface Electromyography with Textile Electrodes in a Smart Leg Sleeve.

Amitrano F, Coccia A, Pagano G, Biancardi A, Tombolini G, Marsico V Sensors (Basel). 2024; 24(9).

PMID: 38732868 PMC: 11086330. DOI: 10.3390/s24092763.


Fabrication and Evaluation of Embroidery-Based Electrode for EMG Smart Wear Using Moss Stitch Technique.

Rho S, Kim H, Lim D, Jeong W Sensors (Basel). 2023; 23(21).

PMID: 37960710 PMC: 10648407. DOI: 10.3390/s23219012.


Recent Advances and Challenges in Textile Electrodes for Wearable Biopotential Signal Monitoring: A Comprehensive Review.

Vidhya C, Maithani Y, Singh J Biosensors (Basel). 2023; 13(7).

PMID: 37504078 PMC: 10377545. DOI: 10.3390/bios13070679.


Evaluation of Novel Embroidered Textile-Electrodes Made from Hybrid Polyamide Conductive Threads for Surface EMG Sensing.

Etana B, Malengier B, Kwa T, Krishnamoorthy J, Van Langenhove L Sensors (Basel). 2023; 23(9).

PMID: 37177601 PMC: 10181695. DOI: 10.3390/s23094397.


Fabrication of Textile-Based Dry Electrode and Analysis of Its Surface EMG Signal for Applying Smart Wear.

Kim H, Rho S, Han S, Lim D, Jeong W Polymers (Basel). 2022; 14(17).

PMID: 36080714 PMC: 9460933. DOI: 10.3390/polym14173641.


References
1.
Ankhili A, Tao X, Cochrane C, Koncar V, Coulon D, Tarlet J . Ambulatory Evaluation of ECG Signals Obtained Using Washable Textile-Based Electrodes Made with Chemically Modified PEDOT:PSS. Sensors (Basel). 2019; 19(2). PMC: 6359744. DOI: 10.3390/s19020416. View

2.
Taelman J, Adriaensen T, van der Horst C, Linz T, Spaepen A . Textile integrated contactless EMG sensing for stress analysis. Annu Int Conf IEEE Eng Med Biol Soc. 2007; 2007:3966-9. DOI: 10.1109/IEMBS.2007.4353202. View

3.
Finni T, Hu M, Kettunen P, Vilavuo T, Cheng S . Measurement of EMG activity with textile electrodes embedded into clothing. Physiol Meas. 2007; 28(11):1405-19. DOI: 10.1088/0967-3334/28/11/007. View

4.
Comert A, Honkala M, Hyttinen J . Effect of pressure and padding on motion artifact of textile electrodes. Biomed Eng Online. 2013; 12:26. PMC: 3637835. DOI: 10.1186/1475-925X-12-26. View

5.
Rattfalt L, Bjorefors F, Nilsson D, Wang X, Norberg P, Ask P . Properties of screen printed electrocardiography smartware electrodes investigated in an electro-chemical cell. Biomed Eng Online. 2013; 12:64. PMC: 3716966. DOI: 10.1186/1475-925X-12-64. View