Abstract

In standard critical care practice, cuff sphygmomanometry is widely used for intermittent blood pressure (BP) measurements. However, cuff devices offer ample possibility of modulating blood flow and pulse propagation along the artery. We explore underutilized arrangements of sensors involving cuff devices which could be of use in critical care to reveal additional information on compensatory mechanisms. In our previous work, we analyzed the response of the vasculature to occlusion perturbations by means of observations obtained non-invasively. In this study, our aim is to (1) acquire additional insights by means of invasive measurements and (2) based on these insights, further develop cuff-based measurement strategies. Invasive BP experimental data is collected downstream from the cuff in two patients monitored in the OR. It is found that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by 20 mmHg, leading to a decrease in pulse transit time by 20 ms. Previous characterizations neglected such distal vasculature effects. A model is developed to reproduce the observed behaviors and to provide a possible explanation of the factors that influence the distal arm mechanisms. We apply the new findings to further develop measurement strategies aimed at acquiring information on pulse arrival time vs. BP calibration, artery compliance, peripheral resistance, artery-vein interaction.

Citing Articles

Towards continuous non-invasive blood pressure measurements-interpretation of the vasculature response to cuff inflation.

Loureiro J, Bogatu L, Schmitt L, Henriques J, Carvalho P, Noordergraaf G Front Physiol. 2023; 14:1172688.

PMID: 37334047 PMC: 10272798. DOI: 10.3389/fphys.2023.1172688.


New Hemodynamic Parameters in Peri-Operative and Critical Care-Challenges in Translation.

Bogatu L, Turco S, Mischi M, Schmitt L, Woerlee P, Bezemer R Sensors (Basel). 2023; 23(4).

PMID: 36850819 PMC: 9961222. DOI: 10.3390/s23042226.

References
1.
Jansen J, Maas J, Pinsky M . Bedside assessment of mean systemic filling pressure. Curr Opin Crit Care. 2010; 16(3):231-6. DOI: 10.1097/MCC.0b013e3283378185. View

2.
Seagar A, Gibbs J, Davis F . Interpretation of venous occlusion plethysmographic measurements using a simple model. Med Biol Eng Comput. 1984; 22(1):12-8. DOI: 10.1007/BF02443739. View

3.
Pinsky M . Functional hemodynamic monitoring. Crit Care Clin. 2014; 31(1):89-111. PMC: 4250574. DOI: 10.1016/j.ccc.2014.08.005. View

4.
Vincent J, Rhodes A, Perel A, Martin G, Rocca G, Vallet B . Clinical review: Update on hemodynamic monitoring--a consensus of 16. Crit Care. 2011; 15(4):229. PMC: 3387592. DOI: 10.1186/cc10291. View

5.
Babbs C . Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical model. Biomed Eng Online. 2012; 11:56. PMC: 3541069. DOI: 10.1186/1475-925X-11-56. View