» Articles » PMID: 34378906

Sample-to-Answer Robotic ELISA

Overview
Journal Anal Chem
Specialty Chemistry
Date 2021 Aug 11
PMID 34378906
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Enzyme-linked immunosorbent assays (ELISA), as one of the most used immunoassays, have been conducted ubiquitously in hospitals, research laboratories, etc. However, the conventional ELISA procedure is usually laborious, occupies bulky instruments, consumes lengthy operation time, and relies considerably on the skills of technicians, and such limitations call for innovations to develop a fully automated ELISA platform. In this paper, we have presented a system incorporating a robotic-microfluidic interface (RoMI) and a modular hybrid microfluidic chip that embeds a highly sensitive nanofibrous membrane, referred to as the Robotic ELISA, to achieve human-free sample-to-answer ELISA tests in a fully programmable and automated manner. It carries out multiple bioanalytical procedures to replace the manual steps involved in classic ELISA operations, including the pneumatically driven high-precision pipetting, efficient mixing and enrichment enabled by back-and-forth flows, washing, and integrated machine vision for colorimetric readout. The Robotic ELISA platform has achieved a low limit of detection of 0.1 ng/mL in the detection of a low sample volume (15 μL) of chloramphenicol within 20 min without human intervention, which is significantly faster than that of the conventional ELISA procedure. Benefiting from its modular design and automated operations, the Robotic ELISA platform has great potential to be deployed for a broad range of detections in various resource-limited settings or high-risk environments, where human involvement needs to be minimized while the testing timeliness, consistency, and sensitivity are all desired.

Citing Articles

A self-driven microfluidic immunosensor for rapid separation, enrichment, and detection of biomarkers in serum.

Zhong Z, Dong J, Xia L, He J, Li G Anal Bioanal Chem. 2024; .

PMID: 39215774 DOI: 10.1007/s00216-024-05490-8.


Automation and Computerization of (Bio)sensing Systems.

Raju C, Elpa D, Urban P ACS Sens. 2024; 9(3):1033-1048.

PMID: 38363106 PMC: 10964247. DOI: 10.1021/acssensors.3c01887.


In Situ Synthesis of Highly Fluorescent, Phosphorus-Doping Carbon-Dot-Functionalized, Dendritic Silica Nanoparticles Applied for Multi-Component Lateral Flow Immunoassay.

Hu J, Ding S Sensors (Basel). 2024; 24(1).

PMID: 38202881 PMC: 10780618. DOI: 10.3390/s24010019.


"Glow ELISA": sensitive immunoassay with minimal equipment and stable reagents.

Vu B, Brosamer K, McDaniel N, Kourentzi K, Willson R, Fernando H Analyst. 2023; 148(22):5582-5587.

PMID: 37819257 PMC: 10658793. DOI: 10.1039/d3an01623d.


Recent Advances in CRISPR/Cas-Based Biosensors for Protein Detection.

Wang J, Yang X, Wang X, Wang W Bioengineering (Basel). 2022; 9(10).

PMID: 36290480 PMC: 9598526. DOI: 10.3390/bioengineering9100512.


References
1.
Apilux A, Ukita Y, Chikae M, Chailapakul O, Takamura Y . Development of automated paper-based devices for sequential multistep sandwich enzyme-linked immunosorbent assays using inkjet printing. Lab Chip. 2012; 13(1):126-35. DOI: 10.1039/c2lc40690j. View

2.
Li F, You M, Li S, Hu J, Liu C, Gong Y . Paper-based point-of-care immunoassays: Recent advances and emerging trends. Biotechnol Adv. 2019; 39:107442. DOI: 10.1016/j.biotechadv.2019.107442. View

3.
Sanjay S, Li M, Zhou W, Li X, Li X . A reusable PMMA/paper hybrid plug-and-play microfluidic device for an ultrasensitive immunoassay with a wide dynamic range. Microsyst Nanoeng. 2021; 6:28. PMC: 8433292. DOI: 10.1038/s41378-020-0143-5. View

4.
Kim J, Jensen E, Megens M, Boser B, Mathies R . Integrated microfluidic bioprocessor for solid phase capture immunoassays. Lab Chip. 2011; 11(18):3106-12. DOI: 10.1039/c1lc20407f. View

5.
Lequin R . Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA). Clin Chem. 2005; 51(12):2415-8. DOI: 10.1373/clinchem.2005.051532. View