» Articles » PMID: 34367699

TAD's for the Derotation of 90° Rotated Maxillary Bicuspids

Overview
Journal Case Rep Dent
Publisher Wiley
Specialty Dentistry
Date 2021 Aug 9
PMID 34367699
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

It is undeniable that the advent of extra-alveolar mini-implants for anchorage purposes has revolutionized the field of Orthodontics. This case report sheds light on an innovative anchorage plan using TADs, to carry out treatment for a 15-year-old female patient. The patient reported to the clinic with a chief complaint of rotated second premolars, crowding, and a deep bite. On examination, it was seen that the patient had a Class I skeletal pattern, Class II subdivision molar relationship, 90-degree maxillary second premolar rotations, crowding in both the arches, and a deep bite. In this case, the clinicians decided to use TADs for premolar derotation as it not only provides a pure rotational couple without any deleterious effects on the adjacent teeth but also helps shorten the overall treatment time. The total treatment time for this case was 10 months.

Citing Articles

Surface Analysis of Orthodontic Mini-Implants after Their Clinical Use.

Ioana T, Boeru F, Antoniac I, Mitrut I, Staicu I, Rauten A J Funct Biomater. 2024; 15(9).

PMID: 39330220 PMC: 11433500. DOI: 10.3390/jfb15090244.


MH-SETUP, combining Kesling wax-setup with indirect bonding and custom-made brackets for labial/lingual techniques to eliminate the finishing phase.

Elkolaly M, Hasan H J Orthod Sci. 2023; 12:11.

PMID: 37351394 PMC: 10282520. DOI: 10.4103/jos.jos_60_22.


The Effects of Intrusion of Anterior Teeth by Skeletal Anchorage in Deep Bite Patients; A Systematic Review and Meta-Analysis.

Bardideh E, Tamizi G, Shafaee H, Rangrazi A, Ghorbani M, Kerayechian N Biomimetics (Basel). 2023; 8(1).

PMID: 36975331 PMC: 10046359. DOI: 10.3390/biomimetics8010101.


MH cortical screws, a revolutionary orthodontic TADs design.

Elkolaly M, Hasan H J Orthod Sci. 2022; 11:53.

PMID: 36411811 PMC: 9674939. DOI: 10.4103/jos.jos_49_22.


The MH-WIRE, a novel coil-springe wire system: A prototype design.

Elkolaly M, Hasan H J Orthod Sci. 2022; 11:33.

PMID: 36188202 PMC: 9515567. DOI: 10.4103/jos.jos_9_22.


References
1.
Elkholy F, Mikhaiel B, Schmidt F, Lapatki B . Mechanical load exerted by PET-G aligners during mesial and distal derotation of a mandibular canine : An in vitro study. J Orofac Orthop. 2017; 78(5):361-370. DOI: 10.1007/s00056-017-0090-4. View

2.
Carano A, Velo S, Leone P, Siciliani G . Clinical applications of the Miniscrew Anchorage System. J Clin Orthod. 2005; 39(1):9-24. View

3.
Almeida M . Biomechanics of extra-alveolar mini-implants. Dental Press J Orthod. 2019; 24(4):93-109. PMC: 6733231. DOI: 10.1590/2177-6709.24.4.093-109.sar. View

4.
Lee K, Park Y, Hwang W, Seong E . Uprighting mandibular second molars with direct miniscrew anchorage. J Clin Orthod. 2008; 41(10):627-35. View

5.
Chang C, Lin J, Yeh H . Extra-Alveolar Bone Screws for Conservative Correction of Severe Malocclusion Without Extractions or Orthognathic Surgery. Curr Osteoporos Rep. 2018; 16(4):387-394. DOI: 10.1007/s11914-018-0465-5. View