Abstract

Objectives: To examine the feasibility of performing ASL-MRI in paediatric patients with solid abdominal tumours.

Methods: Multi-delay ASL data sets were acquired in ten paediatric patients diagnosed with either a neuroblastoma (n = 4) or nephroblastoma (n = 6) during a diagnostic MRI examination at a single visit (n = 4 at initial staging, n = 2 neuroblastoma and n = 2 nephroblastoma patients; n = 6 during follow-up, n = 2 neuroblastoma and n = 4 nephroblastoma patients). Visual evaluation and region-of-interest (ROI) analyses were performed on the processed perfusion-weighted images to assess ASL perfusion signal dynamics in the whole tumour, contralateral kidney, and tumour sub-regions with/without contrast enhancement.

Results: The majority of the included abdominal tumours presented with relatively low perfusion-weighted signal (PWS), especially compared with the highly perfused kidneys. Within the tumours, regions with high PWS were observed which, at short PLD, are possibly related to labelled blood inside vessels and at long PLD, reflect labelled blood accumulating inside tumour tissue over time. Conversely, comparison of ASL perfusion-weighted image findings with Tw enhancement after contrast administration showed that regions lacking contrast enhancement also were void of PWS.

Discussion: This pilot study demonstrates the feasibility of utilizing ASL-MRI in paediatric patients with solid abdominal tumours and provides a basis for further research on non-invasive perfusion measurements in this study population.

Citing Articles

Quantitative MRI in Childhood Neuroblastoma: Beyond the Assessment of Image-defined Risk Factors.

Wang H, Cai J Radiol Imaging Cancer. 2024; 6(6):e240089.

PMID: 39485111 PMC: 11615636. DOI: 10.1148/rycan.240089.

References
1.
Klein S, Staring M, Murphy K, Viergever M, Pluim J . elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 2009; 29(1):196-205. DOI: 10.1109/TMI.2009.2035616. View

2.
Qin Q, van Zijl P . Velocity-selective-inversion prepared arterial spin labeling. Magn Reson Med. 2015; 76(4):1136-48. PMC: 4848210. DOI: 10.1002/mrm.26010. View

3.
Kikuchi K, Hiwatashi A, Togao O, Yamashita K, Yoshimoto K, Mizoguchi M . Correlation between arterial spin-labeling perfusion and histopathological vascular density of pediatric intracranial tumors. J Neurooncol. 2017; 135(3):561-569. DOI: 10.1007/s11060-017-2604-8. View

4.
de Vis J, Hendrikse J, Groenendaal F, de Vries L, Kersbergen K, Benders M . Impact of neonate haematocrit variability on the longitudinal relaxation time of blood: Implications for arterial spin labelling MRI. Neuroimage Clin. 2014; 4:517-25. PMC: 3984444. DOI: 10.1016/j.nicl.2014.03.006. View

5.
Odudu A, Nery F, Harteveld A, Evans R, Pendse D, Buchanan C . Arterial spin labelling MRI to measure renal perfusion: a systematic review and statement paper. Nephrol Dial Transplant. 2018; 33(suppl_2):ii15-ii21. PMC: 6106644. DOI: 10.1093/ndt/gfy180. View