Does Robotic Assisted Technology Improve the Accuracy of Acetabular Component Positioning in Patients with DDH?

Overview
Publisher Sage Publications
Specialty Orthopedics
Date 2021 Jul 26
PMID 34308688
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Accurate positioning of the acetabular component is key in performing total hip arthroplasty (THA). However, reconstruction of the acetabulum in the setting of developmental dysplasia of the hip (DDH) is a challenge. Robotic assisted THA has the potential to improve the accuracy of implantation of the acetabular cup in cases with DDH. The purpose of this study was to assess whether robotic technology improves the accuracy of acetabular component positioning in patients with DDH.

Material And Methods: We included 59 THAs using robotic assisted technology from June 2019 to January 2020 as the study group. These were compared to conventional THAs without robotic technology after control for age, gender, body mass index (BMI), Crowe type and operation date. Radiographic measurements were taken by 2 blinded orthopaedic residents. The percentage of hips within the Lewinnek and Collanan safe zones were calculated, along with acetabular rotation centers for the "target zone." Surgical time and perioperative bleeding were also compared between both groups.

Results: One patient suffered dislocation in conventional group while no dislocation occurred in robotic group. The acetabular components of the robotic assisted group had more cases located within the Lewinnek ( = 0.013) and Collanan ( = 0.008) safe zones than conventional group (94.9% vs 79.7% and 74.6% vs 50.8%). There were 7 cases in conventional group and 4 cases in robotic group that had more lateral or more superior rotational centers of THA, but did not reach statistical significance ( = 0.342). No statistical difference was detected between groups with regards to blood loss ( = 0.098) and surgical time ( = 0.602).

Conclusion: Robot assisted technology can assist surgeons with implanting acetabular cups more in Lewinnek and Callanan safe zone than conventional techniques without additional blood loss and surgical time.

Level Of Evidence: Therapeutic Level Ⅲ.

Citing Articles

Robot-assisted percutaneous cannulated screw fixation in the treatment of slipped capital femoral epiphysis.

Xu Y, Fu G, Feng C, Huang L, Ma Y, Zhang Y J Child Orthop. 2025; :18632521251319987.

PMID: 39959673 PMC: 11829277. DOI: 10.1177/18632521251319987.


Robotically Assisted vs. Manual Total Hip Arthroplasty in Developmental Hip Dysplasia: A Comparative Analysis of Radiological and Functional Outcomes.

Zora H, Bayrak G, Bilgen O J Clin Med. 2025; 14(2).

PMID: 39860515 PMC: 11766202. DOI: 10.3390/jcm14020509.


Optimizing Acetabular Positioning: A Comprehensive Review of Contemporary Strategies in Total Hip Arthroplasty.

Teja T, Shrivastava S, Choudhary A, Rathod V, Balusani P Cureus. 2024; 16(4):e59114.

PMID: 38803755 PMC: 11128723. DOI: 10.7759/cureus.59114.


Are robotic-assisted and computer-navigated total hip arthroplasty associated with superior outcomes in patients who have hip dysplasia?.

Hecht 2nd C, Nedder V, Porto J, Morgan K, Kamath A J Orthop. 2024; 53:125-132.

PMID: 38515529 PMC: 10950562. DOI: 10.1016/j.jor.2024.03.004.


Robotic-assisted total hip arthroplasty in patients with developmental dysplasia of the hip.

Zhang S, Ma M, Kong X, Zhou Y, Chen J, Chai W Int Orthop. 2024; 48(5):1189-1199.

PMID: 38358516 DOI: 10.1007/s00264-024-06115-6.