An Open-Source Monitor-Independent Movement Summary for Accelerometer Data Processing
Overview
Affiliations
Background: Physical behavior researchers using motion sensors often use acceleration summaries to visualize, clean, and interpret data. Such output is dependent on device specifications (e.g., dynamic range, sampling rate) and/or are proprietary, which invalidate cross-study comparison of findings when using different devices. This limits flexibility in selecting devices to measure physical activity, sedentary behavior, and sleep.
Purpose: Develop an open-source, universal acceleration summary metric that accounts for discrepancies in raw data among research and consumer devices.
Methods: We used signal processing techniques to generate a Monitor-Independent Movement Summary unit (MIMS-unit) optimized to capture normal human motion. Methodological steps included raw signal harmonization to eliminate inter-device variability (e.g., dynamic g-range, sampling rate), bandpass filtering (0.2-5.0 Hz) to eliminate non-human movement, and signal aggregation to reduce data to simplify visualization and summarization. We examined the consistency of MIMS-units using orbital shaker testing on eight accelerometers with varying dynamic range (±2 to ±8 g) and sampling rates (20-100 Hz), and human data (N = 60) from an ActiGraph GT9X.
Results: During shaker testing, MIMS-units yielded lower between-device coefficient of variations than proprietary ActiGraph and ENMO acceleration summaries. Unlike the widely used ActiGraph activity counts, MIMS-units were sensitive in detecting subtle wrist movements during sedentary behaviors.
Conclusions: Open-source MIMS-units may provide a means to summarize high-resolution raw data in a device-independent manner, thereby increasing standardization of data cleaning and analytical procedures to estimate selected attributes of physical behavior across studies.
Xiao Q, Feng Q, Rutter M, Albalak G, Wang H, Noordam R Diabetologia. 2025; .
PMID: 39982484 DOI: 10.1007/s00125-025-06368-9.
Patterns of physical activity in hunter-gatherer children compared with US and UK children.
Kretschmer L, Dyble M, Chaudhary N, Bann D, Salali G Sci Rep. 2025; 15(1):1495.
PMID: 39885256 PMC: 11782480. DOI: 10.1038/s41598-024-81326-w.
Contextual Biases in Microinteraction Ecological Momentary Assessment (μEMA) Non-response.
Ponnada A, Li J, Wang S, Wang W, DO B, Dunton G Proc ACM Interact Mob Wearable Ubiquitous Technol. 2025; 6(1).
PMID: 39866712 PMC: 11759496. DOI: 10.1145/3517259.
Sakal C, Zhao W, Xu W, Li X BMC Public Health. 2024; 24(1):3299.
PMID: 39604876 PMC: 11600878. DOI: 10.1186/s12889-024-20115-6.
Sakal C, Li T, Li J, Li X NPJ Aging. 2024; 10(1):56.
PMID: 39587119 PMC: 11589133. DOI: 10.1038/s41514-024-00177-x.