Background: Cardiac catheterization and cardiovascular magnetic resonance (CMR) imaging have distinct diagnostic roles in the congenital heart disease (CHD) population. Invasive CMR (iCMR) allows for a more thorough assessment of cardiac hemodynamics at the same time under the same conditions. It is assumed but not proven that iCMR gives an incremental value by providing more accurate flow quantification.

Methods: Subjects with CHD underwent real-time 1.5 T iCMR using a passive catheter tracking technique with partial saturation pulse of 40° to visualize the gadolinium-filled balloon, CMR-conditional guidewire, and cardiac structures simultaneously to aid in completion of right (RHC) and left heart catheterization (LHC). Repeat iCMR and catheterization measurements were performed to compare reliability by the Pearson (PCC) and concordance correlation coefficients (CCC).

Results: Thirty CHD (20 single ventricle and 10 bi-ventricular) subjects with a median age and weight of 8.3 years (2-33) and 27.7 kg (9.2-80), respectively,  successfully underwent iCMR RHC and LHC. No catheter related complications were encountered. Time taken for first pass RHC and LHC/aortic pull back was 5.1, and 2.9 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 321/328 (98%). One patient with multiple shunts was an outlier and excluded from further analysis. The PCC for catheter-derived pulmonary blood flow (Qp) (0.89, p < 0.001) is slightly lower than iCMR-derived Qp (0.96, p < 0.001), whereas catheter-derived systemic blood flow (Qs) (0.62, p = < 0.001) was considerably lower than iCMR-derived Qs (0.94, p < 0.001). CCC agreement for Qp at baseline (C1-CCC = 0.65, 95% CI 0.41-0.81) and retested conditions (C2-CCC = 0.78, 95% CI 0.58-0.89) were better than for Qs at baseline (C1-CCC = 0.22, 95% CI - 0.15-0.53) and retested conditions (C2-CCC = 0.52, 95% CI 0.17-0.76).

Conclusion: This study further validates hemodynamic measurements obtained via iCMR. iCMR-derived flows have considerably higher test-retest reliability for Qs. iCMR evaluations allow for more reproducible hemodynamic assessments in the CHD population.

Citing Articles

Cardiac catheterization in pulmonary arterial hypertension: Tips and tricks to enhance diagnosis and guide therapy.

Guglielmi G, Krishnathasan K, Constantine A, Dimopoulos K Int J Cardiol Congenit Heart Dis. 2024; 17:100527.

PMID: 39711760 PMC: 11657409. DOI: 10.1016/j.ijcchd.2024.100527.


Emerging multimodality imaging techniques for the pulmonary circulation.

Rajagopal S, Bogaard H, Elbaz M, Freed B, Remy-Jardin M, van Beek E Eur Respir J. 2024; 64(4).

PMID: 39209480 PMC: 11525339. DOI: 10.1183/13993003.01128-2024.


Estimation of pulmonary vascular resistance for Glenn physiology.

Laudenschlager S, Schofield S, Drysdale N, Stone M, Romanowicz J, Frank B PLoS One. 2024; 19(7):e0307890.

PMID: 39058711 PMC: 11280147. DOI: 10.1371/journal.pone.0307890.


Automatic image-based tracking of gadolinium-filled balloon wedge catheters for MRI-guided cardiac catheterization using deep learning.

Neofytou A, Kowalik G, Vidya Shankar R, Huang L, Moon T, Mellor N Front Cardiovasc Med. 2023; 10:1233093.

PMID: 37745095 PMC: 10513169. DOI: 10.3389/fcvm.2023.1233093.


Real-time automatic image-based slice tracking of gadolinium-filled balloon wedge catheter during MR-guided cardiac catheterization: A proof-of-concept study.

Vidya Shankar R, Huang L, Neji R, Kowalik G, Neofytou A, Mooiweer R Magn Reson Med. 2023; 91(1):388-397.

PMID: 37676923 PMC: 10952810. DOI: 10.1002/mrm.29822.


References
1.
Veeram Reddy S, Arar Y, Zahr R, Gooty V, Hernandez J, Potersnak A . Invasive cardiovascular magnetic resonance (iCMR) for diagnostic right and left heart catheterization using an MR-conditional guidewire and passive visualization in congenital heart disease. J Cardiovasc Magn Reson. 2020; 22(1):20. PMC: 7098096. DOI: 10.1186/s12968-020-0605-9. View

2.
James L, Tandon A, Nugent A, Malik S, Ramaciotti C, Greil G . Rationalising the use of cardiac catheterisation before Glenn completion. Cardiol Young. 2018; 28(5):719-724. DOI: 10.1017/S1047951118000240. View

3.
Muthurangu V, Taylor A, Andriantsimiavona R, Hegde S, Miquel M, Tulloh R . Novel method of quantifying pulmonary vascular resistance by use of simultaneous invasive pressure monitoring and phase-contrast magnetic resonance flow. Circulation. 2004; 110(7):826-34. DOI: 10.1161/01.CIR.0000138741.72946.84. View

4.
Arar Y, Veeram Reddy S, Kim H, Dimas V, Zellers T, Zahr R . 3D advanced imaging overlay with rapid registration in CHD to reduce radiation and assist cardiac catheterisation interventions. Cardiol Young. 2020; 30(5):656-662. DOI: 10.1017/S1047951120000712. View

5.
Brown D, Gauvreau K, Powell A, Lang P, Del Nido P, Odegard K . Cardiac magnetic resonance versus routine cardiac catheterization before bidirectional Glenn anastomosis: long-term follow-up of a prospective randomized trial. J Thorac Cardiovasc Surg. 2013; 146(5):1172-8. DOI: 10.1016/j.jtcvs.2012.12.079. View