Simulation of Delivery of Clip-Based Therapies Within Multimodality Images to Facilitate Preprocedural Planning

Citing Articles

HVSMR-2.0: A 3D cardiovascular MR dataset for whole-heart segmentation in congenital heart disease.

Pace D, Contreras H, Romanowicz J, Ghelani S, Rahaman I, Zhang Y Sci Data. 2024; 11(1):721.

PMID: 38956063 PMC: 11219801. DOI: 10.1038/s41597-024-03469-9.


Introduction of transcatheter edge-to-edge repair in patients with congenital heart disease at a children's hospital.

Jolley M, Sulentic A, Amin S, Gupta M, Ching S, Cianciulli A Catheter Cardiovasc Interv. 2023; 103(2):326-334.

PMID: 38149722 PMC: 10911413. DOI: 10.1002/ccd.30935.


Physical Simulation of Transcatheter Edge-to-Edge Repair using Image-Derived 3D Printed Heart Models.

Ching S, Cianciulli A, Flynn M, Silvestro E, Sabin P, Lasso A Ann Thorac Surg Short Rep. 2023; 1(1):40-45.

PMID: 36909146 PMC: 9996204. DOI: 10.1016/j.atssr.2022.09.008.


SlicerHeart: An open-source computing platform for cardiac image analysis and modeling.

Lasso A, Herz C, Nam H, Cianciulli A, Pieper S, Drouin S Front Cardiovasc Med. 2022; 9:886549.

PMID: 36148054 PMC: 9485637. DOI: 10.3389/fcvm.2022.886549.

References
1.
Stone G, Lindenfeld J, Abraham W, Kar S, Lim D, Mishell J . Transcatheter Mitral-Valve Repair in Patients with Heart Failure. N Engl J Med. 2018; 379(24):2307-2318. DOI: 10.1056/NEJMoa1806640. View

2.
Nickenig G, Weber M, Lurz P, von Bardeleben R, Sitges M, Sorajja P . Transcatheter edge-to-edge repair for reduction of tricuspid regurgitation: 6-month outcomes of the TRILUMINATE single-arm study. Lancet. 2019; 394(10213):2002-2011. DOI: 10.1016/S0140-6736(19)32600-5. View

3.
Nguyen A, Lasso A, Nam H, Faerber J, Aly A, Pouch A . Dynamic Three-Dimensional Geometry of the Tricuspid Valve Annulus in Hypoplastic Left Heart Syndrome with a Fontan Circulation. J Am Soc Echocardiogr. 2019; 32(5):655-666.e13. PMC: 6502661. DOI: 10.1016/j.echo.2019.01.002. View

4.
Scanlan A, Nguyen A, Ilina A, Lasso A, Cripe L, Jegatheeswaran A . Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves. Pediatr Cardiol. 2017; 39(3):538-547. PMC: 5831483. DOI: 10.1007/s00246-017-1785-4. View

5.
Nam H, Herz C, Lasso A, Drouin S, Posada A, Morray B . Simulation of Transcatheter Atrial and Ventricular Septal Defect Device Closure Within Three-Dimensional Echocardiography-Derived Heart Models on Screen and in Virtual Reality. J Am Soc Echocardiogr. 2020; 33(5):641-644.e2. PMC: 8083019. DOI: 10.1016/j.echo.2020.01.011. View