» Articles » PMID: 34263384

Development of a Low-Power Instrumented Mouthpiece for Directly Measuring Head Acceleration in American Football

Overview
Journal Ann Biomed Eng
Date 2021 Jul 15
PMID 34263384
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Instrumented mouthpieces (IM) offer a means of measuring head impacts that occur in sport. Direct measurement of angular head kinematics is preferential for accuracy; however, existing IMs measure angular velocity and differentiate the measurement to calculate angular acceleration, which can limit bandwidth and consume more power. This study presents the development and validation of an IM that uses new, low-power accelerometers for direct measurement of linear and angular acceleration over a broad range of head impact conditions in American football. IM sensor accuracy for measuring six-degree-of-freedom head kinematics was assessed using two helmeted headforms instrumented with a custom-fit IM and reference sensor instrumentation. Head impacts were performed at 10 locations and 6 speeds representative of the on-field conditions associated with injurious and non-injurious impacts in American football. Sensor measurements from the IM were highly correlated with those from the reference instrumentation located at the maxilla and skull center of gravity. Based on pooled data across headform and impact location, R ≥ 0.94, mean absolute error (AE) ≤ 7%, and mean relative impact angle ≤ 11° for peak linear and angular acceleration and angular velocity while R ≥ 0.90 and mean AE ≤ 7% for kinematic-based injury metrics used in helmet tests.

Citing Articles

Accuracy of Instrumented Mouthguards During Direct Jaw Impacts Seen in Boxing.

Venkatraman J, Abrams M, Sherman D, Ortiz-Paparoni M, Bercaw J, MacDonald R Ann Biomed Eng. 2024; 52(12):3219-3227.

PMID: 39028399 DOI: 10.1007/s10439-024-03586-x.


Biofidelity and Limitations of Instrumented Mouthguard Systems for Assessment of Rigid Body Head Kinematics.

Abrams M, Venkatraman J, Sherman D, Ortiz-Paparoni M, Bercaw J, MacDonald R Ann Biomed Eng. 2024; 52(10):2872-2883.

PMID: 38910203 DOI: 10.1007/s10439-024-03563-4.


Physiological and Biomechanical Monitoring in American Football Players: A Scoping Review.

Nocera A, Sbrollini A, Romagnoli S, Morettini M, Gambi E, Burattini L Sensors (Basel). 2023; 23(7).

PMID: 37050597 PMC: 10098592. DOI: 10.3390/s23073538.


Padded Helmet Shell Covers in American Football: A Comprehensive Laboratory Evaluation with Preliminary On-Field Findings.

Cecchi N, Callan A, Watson L, Liu Y, Zhan X, Vegesna R Ann Biomed Eng. 2023; 52(10):2703-2716.

PMID: 36917295 PMC: 10013271. DOI: 10.1007/s10439-023-03169-2.


Consensus Head Acceleration Measurement Practices (CHAMP): Laboratory Validation of Wearable Head Kinematic Devices.

Gabler L, Patton D, Begonia M, Daniel R, Rezaei A, Huber C Ann Biomed Eng. 2022; 50(11):1356-1371.

PMID: 36104642 PMC: 9652295. DOI: 10.1007/s10439-022-03066-0.

References
1.
Allison M, Kang Y, Bolte 4th J, Maltese M, Arbogast K . Validation of a helmet-based system to measure head impact biomechanics in ice hockey. Med Sci Sports Exerc. 2013; 46(1):115-23. DOI: 10.1249/MSS.0b013e3182a32d0d. View

2.
Allison M, Kang Y, Maltese M, Bolte 4th J, Arbogast K . Measurement of Hybrid III Head Impact Kinematics Using an Accelerometer and Gyroscope System in Ice Hockey Helmets. Ann Biomed Eng. 2014; 43(8):1896-906. DOI: 10.1007/s10439-014-1197-z. View

3.
Bailey A, Funk J, Lessley D, Sherwood C, Crandall J, Neale W . Validation of a videogrammetry technique for analysing American football helmet kinematics. Sports Biomech. 2018; 19(5):678-700. DOI: 10.1080/14763141.2018.1513059. View

4.
Bailey A, Sanchez E, Park G, Gabler L, Funk J, Crandall J . Development and Evaluation of a Test Method for Assessing the Performance of American Football Helmets. Ann Biomed Eng. 2020; 48(11):2566-2579. DOI: 10.1007/s10439-020-02626-6. View

5.
Bailey A, Sherwood C, Funk J, Crandall J, Carter N, Hessel D . Characterization of Concussive Events in Professional American Football Using Videogrammetry. Ann Biomed Eng. 2020; 48(11):2678-2690. DOI: 10.1007/s10439-020-02637-3. View