» Articles » PMID: 34262232

Parameterization, Geometric Modeling, and Isogeometric Analysis of Tricuspid Valves

Overview
Date 2021 Jul 15
PMID 34262232
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Approximately 1.6 million patients in the United States are affected by tricuspid valve regurgitation, which occurs when the tricuspid valve does not close properly to prevent backward blood flow into the right atrium. Despite its critical role in proper cardiac function, the tricuspid valve has received limited research attention compared to the mitral and aortic valves on the left side of the heart. As a result, proper valvular function and the pathologies that may cause dysfunction remain poorly understood. To promote further investigations of the biomechanical behavior and response of the tricuspid valve, this work establishes a parameter-based approach that provides a template for tricuspid valve modeling and simulation. The proposed tricuspid valve parameterization presents a comprehensive description of the leaflets and the complex chordae tendineae for capturing the typical three-cusp structural deformation observed from medical data. This simulation framework develops a practical procedure for modeling tricuspid valves and offers a robust, flexible approach to analyze the performance and effectiveness of various valve configurations using isogeometric analysis. The proposed methods also establish a baseline to examine the tricuspid valve's structural deformation, perform future investigations of native valve configurations under healthy and disease conditions, and optimize prosthetic valve designs.

Citing Articles

ADEPT: A Noninvasive Method for Determining Elastic Parameters of Valve Tissue.

Wu W, Daneker M, Herz C, Dewey H, Weiss J, Pouch A ArXiv. 2025; .

PMID: 39990796 PMC: 11844617.


Parameterization, algorithmic modeling, and fluid-structure interaction analysis for generative design of transcatheter aortic valves.

Pan X, Corpuz A, Rajanna M, Johnson E Eng Comput. 2024; 40(6):3405-3427.

PMID: 39678645 PMC: 11639685. DOI: 10.1007/s00366-024-01973-5.


Effect of Parametric Variation of Chordae Tendineae Structure on Simulated Atrioventricular Valve Closure.

Mangine N, Laurence D, Sabin P, Wu W, Herz C, Zelonis C ArXiv. 2024; .

PMID: 39606725 PMC: 11601809.


FEBio FINESSE: An Open-Source Finite Element Simulation Approach to Estimate In Vivo Heart Valve Strains Using Shape Enforcement.

Laurence D, Sabin P, Sulentic A, Daemer M, Maas S, Weiss J Ann Biomed Eng. 2024; 53(1):241-259.

PMID: 39499365 PMC: 11831577. DOI: 10.1007/s10439-024-03637-3.


Cardiac tissue engineering: an emerging approach to the treatment of heart failure.

Rayat Pisheh H, Nojabaei F, Darvishi A, Rayat Pisheh A, Sani M Front Bioeng Biotechnol. 2024; 12:1441933.

PMID: 39211011 PMC: 11357970. DOI: 10.3389/fbioe.2024.1441933.


References
1.
Ross C, Hsu M, Baumwart R, Mir A, Burkhart H, Holzapfel G . Quantification of load-dependent changes in the collagen fiber architecture for the strut chordae tendineae-leaflet insertion of porcine atrioventricular heart valves. Biomech Model Mechanobiol. 2020; 20(1):223-241. PMC: 8008705. DOI: 10.1007/s10237-020-01379-4. View

2.
Rausch M, Malinowski M, Wilton P, Khaghani A, Timek T . Engineering Analysis of Tricuspid Annular Dynamics in the Beating Ovine Heart. Ann Biomed Eng. 2017; 46(3):443-451. DOI: 10.1007/s10439-017-1961-y. View

3.
Prihadi E, Delgado V, Hahn R, Leipsic J, Min J, Bax J . Imaging Needs in Novel Transcatheter Tricuspid Valve Interventions. JACC Cardiovasc Imaging. 2018; 11(5):736-754. DOI: 10.1016/j.jcmg.2017.10.029. View

4.
Ross C, Laurence D, Richardson J, Babu A, Evans L, Beyer E . An investigation of the glycosaminoglycan contribution to biaxial mechanical behaviours of porcine atrioventricular heart valve leaflets. J R Soc Interface. 2019; 16(156):20190069. PMC: 6685018. DOI: 10.1098/rsif.2019.0069. View

5.
Muraru D, Veronesi F, Maddalozzo A, Dequal D, Frajhof L, Rabischoffsky A . 3D printing of normal and pathologic tricuspid valves from transthoracic 3D echocardiography data sets. Eur Heart J Cardiovasc Imaging. 2016; 18(7):802-808. DOI: 10.1093/ehjci/jew215. View