» Articles » PMID: 34243739

Application of Bedside Ultrasound in Predicting the Outcome of Weaning from Mechanical Ventilation in Elderly Patients

Overview
Journal BMC Pulm Med
Publisher Biomed Central
Specialty Pulmonary Medicine
Date 2021 Jul 10
PMID 34243739
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Background: With the increased ageing of society, more and more elderly people are admitted to the intensive care unit, How to accurately predict whether elderly patients can successfully wean from the ventilator is more complicated. Diaphragmatic excursion (DE) and diaphragm thickening fraction (DTF) were measured by bedside ultrasound to assess diaphragm function. The lung ultrasound score (LUS) and the rapid shallow breathing index (RBSI) were used as indices of diaphragm function to predict the outcome of weaning from mechanical ventilation. The aim of this study was to examine the clinical utility of these parameters in predicting extubation success.

Methods: This prospective study included 101 consecutive elderly patients undergoing a trial of extubation in the ICU of Haidian Hospital between June 2017 and July 2020. Patients were divided into the successful weaning group (n = 69) and the failed weaning group (n = 32). Baseline characteristics, including RSBI, were recorded. Measurements of DE, DTF and LUS were made using ultrasound within 24 h before extubation.

Results: Median DE was greater in patients with extubation success than in those with extubation failure (1.64 cm vs. 0.78 cm, p = 0.001). Patients with extubation success had a greater DTF than those with extubation failure (49.48% vs. 27.85%, p = 0.001). The areas under the receiver operating curves for the RSBI, LUS, DE and DFT were 0.680, 0.764, 0.831 and 0.881, respectively. The best cut-off values for predicting successful weaning were DTF ≥ 30%, DE ≥ 1.3 cm, LUS ≤ 11, and RSBI ≤ 102. The specificity of DTF (84%) in predicting weaning outcome was higher than that of RBSI (53%), that of LUS (55%), and that of DE (62%). The sensitivity of DTF (94%) was greater than that of RBSI (85%), that of LUS (71%), and that of DE (65%). The combination of RSBI, LUS, DE, and DTF showed the highest AUC (AUC = 0.919), with a sensitivity of 96% and a specificity of 89%.

Conclusions: DTF has higher sensitivity and specificity for the prediction of successful weaning in elderly patients than the other parameters examined. The combination of RSBI, LUS, DE and DFT performed well in predicting weaning outcome. This has potentially important clinical application and merits further evaluation.

Citing Articles

Value of diaphragmatic ultrasound parameters in assessing weaning outcomes and survival in ventilator-dependent intensive care unit patients.

Pan L, Zhao J, Wang X, Huang L, Li S, Sun S Am J Transl Res. 2025; 16(12):7830-7839.

PMID: 39822550 PMC: 11733325. DOI: 10.62347/FDPE7053.


Lung ultrasound score and diaphragm ultrasound in weaning from mechanical ventilation: are they different in patients with and without COVID-19?.

Madeira L, Dalcin P, Schuster G, Conte B, Wolf J, Schreiber A J Bras Pneumol. 2024; 50(5):e20240302.

PMID: 39661844 PMC: 11601084. DOI: 10.36416/1806-3756/e20240302.


Diaphragmatic Dynamics Assessed by Bedside Ultrasound Predict Extubation in the Intensive Care Unit: A Prospective Observational Study.

Zhang T, Liu Y, Xu D, Dong R, Song Y Int J Gen Med. 2024; 17:5373-5380.

PMID: 39582920 PMC: 11584334. DOI: 10.2147/IJGM.S487999.


Weaning Failure in Elderly Patients: A Systematic Review and Meta-Analysis.

Yayan J, Schiffner R J Clin Med. 2024; 13(21).

PMID: 39518568 PMC: 11547008. DOI: 10.3390/jcm13216429.


Effect of low-volume ropivacaine in ultrasound-guided superior trunk block on diaphragmatic movement in patients undergoing shoulder arthroscopy: a randomized controlled trial.

Wang H, Bao Q, Cao D, Zhu L, Chen L, Yu Y J Orthop Surg Res. 2024; 19(1):604.

PMID: 39342253 PMC: 11437893. DOI: 10.1186/s13018-024-05083-2.


References
1.
Abdelwahed W, Abd Elghafar M, Amr Y, Alsherif S, Eltomey M . Prospective study: Diaphragmatic thickness as a predictor index for weaning from mechanical ventilation. J Crit Care. 2019; 52:10-15. DOI: 10.1016/j.jcrc.2019.03.006. View

2.
Macintyre N, Cook D, Ely Jr E, Epstein S, FINK J, Heffner J . Evidence-based guidelines for weaning and discontinuing ventilatory support: a collective task force facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care.... Chest. 2001; 120(6 Suppl):375S-95S. DOI: 10.1378/chest.120.6_suppl.375s. View

3.
Soummer A, Perbet S, Brisson H, Arbelot C, Constantin J, Lu Q . Ultrasound assessment of lung aeration loss during a successful weaning trial predicts postextubation distress*. Crit Care Med. 2012; 40(7):2064-72. DOI: 10.1097/CCM.0b013e31824e68ae. View

4.
Llamas-Alvarez A, Tenza-Lozano E, Latour-Perez J . Diaphragm and Lung Ultrasound to Predict Weaning Outcome: Systematic Review and Meta-Analysis. Chest. 2017; 152(6):1140-1150. DOI: 10.1016/j.chest.2017.08.028. View

5.
Vetrugno L, Guadagnin G, Brussa A, Orso D, Garofalo E, Bruni A . Mechanical ventilation weaning issues can be counted on the fingers of just one hand: part 1. Ultrasound J. 2020; 12(1):9. PMC: 7067937. DOI: 10.1186/s13089-020-00161-y. View