» Articles » PMID: 34237047

Efficacy of Portable Air Cleaners and Masking for Reducing Indoor Exposure to Simulated Exhaled SARS-CoV-2 Aerosols - United States, 2021

Overview
Date 2021 Jul 8
PMID 34237047
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

SARS-CoV-2, the virus that causes COVID-19, can be spread by exposure to droplets and aerosols of respiratory fluids that are released by infected persons when they cough, sing, talk, or exhale. To reduce indoor transmission of SARS-CoV-2 between persons, CDC recommends measures including physical distancing, universal masking (the use of face masks in public places by everyone who is not fully vaccinated), and increased room ventilation (1). Ventilation systems can be supplemented with portable high efficiency particulate air (HEPA) cleaners* to reduce the number of infectious particles in the air and provide enhanced protection from transmission between persons (2); two recent reports found that HEPA air cleaners in classrooms could reduce overall aerosol particle concentrations by ≥80% within 30 minutes (3,4). To investigate the effectiveness of portable HEPA air cleaners and universal masking at reducing exposure to exhaled aerosol particles, the investigation team used respiratory simulators to mimic a person with COVID-19 and other, uninfected persons in a conference room. The addition of two HEPA air cleaners that met the Environmental Protection Agency (EPA)-recommended clean air delivery rate (CADR) (5) reduced overall exposure to simulated exhaled aerosol particles by up to 65% without universal masking. Without the HEPA air cleaners, universal masking reduced the combined mean aerosol concentration by 72%. The combination of the two HEPA air cleaners and universal masking reduced overall exposure by up to 90%. The HEPA air cleaners were most effective when they were close to the aerosol source. These findings suggest that portable HEPA air cleaners can reduce exposure to SARS-CoV-2 aerosols in indoor environments, with greater reductions in exposure occurring when used in combination with universal masking.

Citing Articles

An Outbreak of Respiratory Viral Infections in a Professional Ice Hockey Team.

Gronroos W, Helenius P, Valtonen M, Waris M, Heinonen O, Ruuskanen O Influenza Other Respir Viruses. 2024; 18(11):e70041.

PMID: 39479873 PMC: 11525232. DOI: 10.1111/irv.70041.


Study on the Effectiveness of a Copper Electrostatic Filtration System "Aerok 1.0" for Air Disinfection.

Albertini R, Colucci M, Viani I, Capobianco E, Serpentino M, Coluccia A Int J Environ Res Public Health. 2024; 21(9).

PMID: 39338083 PMC: 11431324. DOI: 10.3390/ijerph21091200.


Effectiveness of a suction device for containment of pathogenic aerosols and droplets.

Lordly K, Karatas A, Lin S, Umapathy K, Mohindra R PLoS One. 2024; 19(7):e0305842.

PMID: 39046940 PMC: 11268607. DOI: 10.1371/journal.pone.0305842.


Air Cleaners and Respiratory Infections in Schools: A Modeling Study Based on Epidemiologic, Environmental, and Molecular Data.

Banholzer N, Jent P, Bittel P, Zurcher K, Furrer L, Bertschinger S Open Forum Infect Dis. 2024; 11(4):ofae169.

PMID: 38665173 PMC: 11045022. DOI: 10.1093/ofid/ofae169.


Ozone Generation from a Germicidal Ultraviolet Lamp with Peak Emission at 222 nm.

Link M, Shore A, Hamadani B, Poppendieck D Environ Sci Technol Lett. 2024; 10(8).

PMID: 38487621 PMC: 10938353. DOI: 10.1021/acs.estlett.3c00318.


References
1.
Luongo J, Fennelly K, Keen J, Zhai Z, Jones B, Miller S . Role of mechanical ventilation in the airborne transmission of infectious agents in buildings. Indoor Air. 2015; 26(5):666-78. PMC: 7165552. DOI: 10.1111/ina.12267. View

2.
Burgmann S, Janoske U . Transmission and reduction of aerosols in classrooms using air purifier systems. Phys Fluids (1994). 2021; 33(3):033321. PMC: 8060972. DOI: 10.1063/5.0044046. View

3.
Morawska L, Allen J, Bahnfleth W, Bluyssen P, Boerstra A, Buonanno G . A paradigm shift to combat indoor respiratory infection. Science. 2021; 372(6543):689-691. DOI: 10.1126/science.abg2025. View

4.
Lindsley W, Beezhold D, Coyle J, Derk R, Blachere F, Boots T . Efficacy of universal masking for source control and personal protection from simulated cough and exhaled aerosols in a room. J Occup Environ Hyg. 2021; 18(8):409-422. PMC: 8355198. DOI: 10.1080/15459624.2021.1939879. View