» Articles » PMID: 34223780

The Performance of Digital Monitoring Devices for Oxygen Saturation and Respiratory Rate in COPD: A Systematic Review

Overview
Journal COPD
Publisher Informa Healthcare
Specialty Pulmonary Medicine
Date 2021 Jul 5
PMID 34223780
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Healthcare access and delivery for individuals with chronic obstructive pulmonary disease (COPD) who live in remote areas or who are susceptible to contracting communicable diseases, such as COVID-19, may be a challenge. Telehealth and remote monitoring devices can be used to overcome this issue. However, the accuracy of these devices must be ensured before forming healthcare decisions based on their outcomes. Therefore, a systematic review was performed to synthesize the evidence on the reliability, validity and responsiveness of digital devices used for tracking oxygen saturation (SpO) and/or respiratory rate (RR) in individuals with COPD, in remote settings. Three electronic databases were searched: MEDLINE (1996 to October 8, 2020), EMBASE (1996 to October 8, 2020) and CINAHL (1998 to October 8, 2020). Studies were included if they aimed to evaluate one or more measurement properties of a digital device measuring SpO or RR in individuals with COPD. Six-hundred and twenty-five articles were identified and after screening, 7 studies matched the inclusion criteria; covering 11 devices measuring SpO and/or RR. Studies reported on the reliability ( = 1), convergent validity ( = 1), concurrent validity ( = 2) and predictive validity ( = 2) of SpO devices and on the convergent validity ( = 1), concurrent validity ( = 1) and predictive validity ( = 1) of RR devices. SpO and RR devices were valid when compared against other respiration monitoring devices but were not precise in predicting exacerbation events. More well-designed measurement studies are needed to make firm conclusions about the accuracy of such devices.Supplemental data for this article is available online at https://doi.org/10.1080/15412555.2021.1945021 .

Citing Articles

Evaluation of Photoplethysmography-Based Monitoring of Respiration Rate During High-Intensity Interval Training: Implications for Healthcare Monitoring.

Muller M, Ebrahimkheil K, Vijgeboom T, van Eijck C, Ronner E Biosensors (Basel). 2024; 14(12).

PMID: 39727896 PMC: 11674237. DOI: 10.3390/bios14120631.


Guideline for reporting systematic reviews of outcome measurement instruments (OMIs): PRISMA-COSMIN for OMIs 2024.

Elsman E, Mokkink L, Terwee C, Beaton D, Gagnier J, Tricco A Qual Life Res. 2024; 33(8):2029-2046.

PMID: 38980635 PMC: 11286641. DOI: 10.1007/s11136-024-03634-y.


Guideline for reporting systematic reviews of outcome measurement instruments (OMIs): PRISMA-COSMIN for OMIs 2024.

Elsman E, Mokkink L, Terwee C, Beaton D, Gagnier J, Tricco A Health Qual Life Outcomes. 2024; 22(1):48.

PMID: 38978063 PMC: 11232333. DOI: 10.1186/s12955-024-02256-9.


Guideline for reporting systematic reviews of outcome measurement instruments (OMIs): PRISMA-COSMIN for OMIs 2024.

Elsman E, Mokkink L, Terwee C, Beaton D, Gagnier J, Tricco A J Patient Rep Outcomes. 2024; 8(1):64.

PMID: 38977535 PMC: 11231111. DOI: 10.1186/s41687-024-00727-7.


Experiences of Patients With Chronic Obstructive Pulmonary Disease Using the Apple Watch Series 6 Versus the Traditional Finger Pulse Oximeter for Home SpO2 Self-Monitoring: Qualitative Study Part 2.

Liu Y, Arnaert A, Costa D, Sumbly P, Debe Z, Charbonneau S JMIR Aging. 2023; 6:e41539.

PMID: 37917147 PMC: 10654900. DOI: 10.2196/41539.