» Articles » PMID: 34222834

Robustness to Misalignment of Low-cost, Compact Quantitative Phase Imaging Architectures

Overview
Journal OSA Contin
Date 2021 Jul 5
PMID 34222834
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Non-interferometric approaches to quantitative phase imaging could enable its application in low-cost, miniaturised settings such as capsule endoscopy. We present two possible architectures and both analyse and mitigate the effect of sensor misalignment on phase imaging performance. This is a crucial step towards determining the feasibility of implementing phase imaging in a capsule device. First, we investigate a design based on a folded 4f correlator, both in simulation and experimentally. We demonstrate a novel technique for identifying and compensating for axial misalignment and explore the limits of the approach. Next, we explore the implications of axial and transverse misalignment, and of manufacturing variations on the performance of a phase plate-based architecture, identifying a clear trade-off between phase plate resolution and algorithm convergence time. We conclude that while the phase plate architecture is more robust to misalignment, both architectures merit further development with the goal of realising a low-cost, compact system for applying phase imaging in capsule endoscopy.

Citing Articles

Quantitative Phase Imaging: Recent Advances and Expanding Potential in Biomedicine.

Nguyen T, Pradeep S, Judson-Torres R, Reed J, Teitell M, Zangle T ACS Nano. 2022; 16(8):11516-11544.

PMID: 35916417 PMC: 10112851. DOI: 10.1021/acsnano.1c11507.

References
1.
Latychevskaia T, Fink H . Solution to the twin image problem in holography. Phys Rev Lett. 2007; 98(23):233901. DOI: 10.1103/PhysRevLett.98.233901. View

2.
Polans J, McNabb R, Izatt J, Farsiu S . Compressed wavefront sensing. Opt Lett. 2014; 39(5):1189-92. PMC: 4095882. DOI: 10.1364/OL.39.001189. View

3.
Switz N, DAmbrosio M, Fletcher D . Low-cost mobile phone microscopy with a reversed mobile phone camera lens. PLoS One. 2014; 9(5):e95330. PMC: 4031072. DOI: 10.1371/journal.pone.0095330. View

4.
Tseng D, Mudanyali O, Oztoprak C, Isikman S, Sencan I, Yaglidere O . Lensfree microscopy on a cellphone. Lab Chip. 2010; 10(14):1787-92. PMC: 2941438. DOI: 10.1039/c003477k. View

5.
Wang C, Fu Q, Dun X, Heidrich W . Quantitative Phase and Intensity Microscopy Using Snapshot White Light Wavefront Sensing. Sci Rep. 2019; 9(1):13795. PMC: 6760235. DOI: 10.1038/s41598-019-50264-3. View