» Articles » PMID: 34211007

Extraction of Apex Beat Waveform from Acoustic Pulse Wave by Sound Sensing System Using Stochastic Resonance

Overview
Journal Sci Rep
Specialty Science
Date 2021 Jul 2
PMID 34211007
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

With a sound sensing system using stochastic resonance (4SR), it became possible to obtain an acoustic pulse wave (APW)-a waveform created via a mixture of apex beat and heart sound. We examined 50 subjects who were healthy, with no underlying cardiovascular diseases. We could determine boundary frequency (BF) using APW and phonocardiogram signals. APW data was divided into two bands, one from 0.5 Hz to BF, and a second one from BF to 50 Hz. This permitted the extraction of cardiac apex beat (CAB) and cardiac acoustic sound (CAS), respectively. BF could be expressed by a quadratic function of heart rate, and made it possible to collect CAB and CAS in real time. According to heart rate variability analysis, the fluctuation was 1/f, which indicated an efficient cardiac movement when heart rate was 70 to 80/min. In the frequency band between 0.5 Hz and BF, CAB readings collected from the precordial region resembled apex cardiogram data. The waveforms were classified into five types. Therefore, the new 4SR sensing system can be used as a physical diagnostic tool to obtain biological pulse wave data non-invasively and repeatedly over a long period, and it shows promise for broader applications, including AI analysis.

Citing Articles

Verification of a system utilizing heartbeat-induced acoustic pulse waves for estimating the time at which bladder urine increases to a level requiring drainage among individuals with spinal cord injury.

Suzuki H, Tsujimura H, Kitahara T, Taoda K, Ogura Y, Fujita E Biomed Eng Online. 2024; 23(1):126.

PMID: 39702352 PMC: 11660832. DOI: 10.1186/s12938-024-01317-w.


I. Lessons learnt from pandemics of the past and present & critical areas of research to face future pandemics.

Levy G J Stem Cells Regen Med. 2022; 17(2):63-64.

PMID: 35250205 PMC: 8866801. DOI: 10.46582/jsrm.1702011.

References
1.
Jafari Tadi M, Lehtonen E, Saraste A, Tuominen J, Koskinen J, Teras M . Gyrocardiography: A New Non-invasive Monitoring Method for the Assessment of Cardiac Mechanics and the Estimation of Hemodynamic Variables. Sci Rep. 2017; 7(1):6823. PMC: 5533710. DOI: 10.1038/s41598-017-07248-y. View

2.
Hayano J, Yamasaki F, Sakata S, Okada A, Mukai S, FUJINAMI T . Spectral characteristics of ventricular response to atrial fibrillation. Am J Physiol. 1998; 273(6):H2811-6. DOI: 10.1152/ajpheart.1997.273.6.H2811. View

3.
Kobayashi M, Musha T . 1/f fluctuation of heartbeat period. IEEE Trans Biomed Eng. 1982; 29(6):456-7. DOI: 10.1109/TBME.1982.324972. View

4.
Hagiyama N, Hirano H, Mito A, Soh Z, Fujita E, Ogura Y . Unconstrained Vital Sign Monitoring System Using an Aortic Pulse Wave Sensor. Sci Rep. 2019; 9(1):17475. PMC: 6877648. DOI: 10.1038/s41598-019-53808-9. View

5.
You I, Kim B, Park J, Koh K, Shin S, Jung S . Stretchable E-Skin Apexcardiogram Sensor. Adv Mater. 2016; 28(30):6359-64. DOI: 10.1002/adma.201600720. View